7.1
Impostazione Forza e rallentamenti
We suggest you to check the correct function of the accessories and motors with
R
function as shown in Par.
3.2. Adjust the force, slowing down, obstacle detection and ckeck the parameters. After adjust the slowing
down position and the working time. At the end programm the working time. It is possible to change the va
-
lues after the learning of the working time.
L 01
L 03
FORCE LEVEL MOT 1
From 0 to 100
(0 = min / 100 = max)
Standard Value 70
FORCE LEVEL MOT 2
From 0 to 100
(0 = min / 100 = max)
Standard Value 70
L 02
L 04
SLOWING DOWN MOT 1
From 0 to 100 / 100 = OFF
Standard Value 10
SLOWING DOWN MOT 2
From 0 to 100 / 100 = OFF
Standard Value 10
7.2
Obstacle detection
L 05
Level of detection
obstacle or LS of motor 1
From 0 to 100 / 0 = OFF
Standard Value 30
L 06
L 07
Level of detection
obstacle or LS of motor 2
From 0 to 100 / 0 = OFF
Standard Value 30
Level of detection
obstacle or LS of motor 1
slowing down
From 0 to 100 / 0 = OFF
Standard Value 0
L 08
Level of detection
obstacle or LS of motor 2
slowing down
From 0 to 100 / 0 = OFF
Standard Value 0
7
Force and slow down adjustment
we recommend not to increase the
sensitivity, the gate cannot work properly.
!
Try the correct force
and speed adjust
-
ment with function R
as shown in Par. 3.2
!
S 20
Logic of the
obstacle
detection
01
02
03
considered as LS
(Standard)
Considered
as STOP
Considered as
STOP with motor
renverse 2s
wARNING. Try the correct force
and speed adjustment with