Detected voltages are described in the next table and diagram:
TYPICAL DETECTED VOLTAGES AT POWER LEVELS PL2
…
PL10
HD965
800D
1900
D
Pout
TXC
LB–DETO
Pout
TXC
UB–
DETO
PL
dBm
dac
mV
PL
dBm
dac
mV
2
26.8
183
1560
2
25.2
15
1260
3
23.5
16
1230
3
23.3
–53
1090
4
19.8
–108
980
4
19.3
–163
880
5
15.8
–195
800
5
15.3
–230
730
6
11.8
–250
680
6
11.3
–275
640
7
7.8
–296
630
7
7.3
–307
580
8
3.8
–265
690
8
3.3
–287
610
9
–0.2
–306
610
9
–0.2
–318
560
10
–3.8
–343
550
10
–3.8
–347
500
NOTE:
DAC VALUES MAY VARY +/– 150 DAC UNITS
0
200
400
600
800
1000
1200
1400
1600
1800
2
4
6
8
10
Power level
Detected voltage [mV]
800D