10.
SNMP Server Configuration
MN700004 Rev 01
100
The view is displayed in the following format:
ipCidrRouteEntry.192.168.0.0.255.255.0.0.0.192.168.4.1
device-name
#
show snmp-server view
View name: MyView
OID: mib-2 included
Row status: Active
Storage type:Volatile
View name: MyView
OID: sysUpTime excluded
Row status: Active
Storage type:Volatile
device-name
#
If the file
batm_oid_table
is loaded in the hidden directory of the flash file system, the OIDs
will be shown with symbolic names.
The row status can be
Active
(the row is operable) or
notInService
(the row is
administratively disabled).
The storage type can be
Volatile
(the data is in volatile memory, and after reboot it will be
lost) or
Non Volatile
(the data is in Non volatile memory – it will be restored after reboot).
Displaying the Notification Target Parameters
The
show snmp-server target-param
command, in Privileged (Enable) mode, displays the
notification target parameters.
Command Syntax
device-name
#
show snmp-server target-param
Example
device-name
#
show snmp-server target-param
Target Parameter: param1
Security Name: GHJ
Security Level: auth
Profile name: PROFILE
device-name
#
Displaying the Notification Target Profiles
The
show snmp-server target-profiles
command, in Privileged (Enable) mode, displays the
notification target profiles.
Command Syntax
device-name
#
show snmp-server target-profiles
Example
device-name
#
show snmp-server target-profiles