27
Battery not connected
Connect the battery correctly
The fuse is faulty
Check and eventually replace fuses
Battery discharged
Charge the battery
Emergency button is activated
De-activate the button by
inserting and pulling the
knob.
Only travelling in one
direction
The accelerator and the connections are
damaged.
Check the accelerator and the
connections.
The truck only
travels very slowly
The battery is discharged.
Check the battery status at the
discharge indicator
The electromagnetic brake is engaged.
Check the electromagnetic brake
The
relating
tiller
cables
are
disconnected or damaged
Check
the
tiller
cables
and
connections.
Electric system overheated
Stop using and cool down the truck
Heat sensor failure
Check and if necessary replace the
heat sensor
The truck starts up
suddenly
The controller is damaged.
Replace the controller.
The accelerator not moves back to its
neutral position.
Repair or replace the accelerator.
If the truck has malfuncti
ons and can’t be operated out of the working zone, jack the truck up and
go with a load handler under the truck and safe the truck securely. Then move the truck out of the
aisle.
Summary of Contents for RT16P
Page 7: ...b Main technical data Fig 2 Structure schematic drawing...
Page 30: ...28 10 WIRING CIRCUIT DIAGRAM Electrical circuit diagram Fig 16 Electrical circuit diagram...
Page 32: ...30 a Hydraulic circuit Fig 17 Hydraulic circuit...
Page 34: ...32...
Page 35: ...33...
Page 36: ...34...
Page 37: ...35...
Page 38: ...36...
Page 39: ...37...
Page 40: ...38...
Page 41: ...39...
Page 42: ...40...
Page 44: ...42 1222 Steering motor controller and pump motor controller fault code table...
Page 45: ...43...
Page 46: ...44...
Page 47: ...45...
Page 48: ...46...