![noax N11 User Manual Download Page 98](http://html1.mh-extra.com/html/noax/n11/n11_user-manual_1697726098.webp)
User Manual N11
Technical data
Industrial PC
www.noax.com
Page 98 of 120
3085-US-2.4
15.2.7 Device type Steel - S15‐G2
General
Dimensions ( L x W x H ):
16.5 inches x 14.2 inches x 5.2 inches
(418 mm x 360 mm x 133 mm)
Weight (depending on setup):
approx. 31.3 lb (approx. 14.2 kg)
Front and housing:
Stainless steel V2A (1.4301)
Touchscreen:
Analog resistive touchscreen
Power supply requirements
Rated input voltage:
100 V to 236 V AC (alternating current)
Nominal frequency range
47 – 63 Hz
Max. input current:
2.0 A
Power supply requirements with option “Without internal power supply”
Rated input voltage:
+24 V DC (direct current)
Input voltage range:
18 V to 30 V DC (direct current)
Input current:
Max. 5.0 A
Display (38.1 cm / 15 inches – XGA)
Size / Type:
38.1 cm / 15 inches / TFT
Resolution:
XGA 1024 x 768
Viewable color depth:
24 Bit
Brightness:
Typ. 400 cd/m
2
IP protection class as per DIN EN 60529
Housing protection class
IP69k (with suitable connector protection)
Ambient temperature
Start‐up temperature:
32°F to 104°F (0°C to +40°C)
Operating temperature:
23°F to 104°F (-5°C to +40°C)
Ambient temperature with option “Extended pos. temperature range”
Start‐up temperature:
32°F to 122°F (0°C to +50°C)
Operating temperature:
23°F to 122°F (-5°C to +50°C)
Ambient temperature with option “Extended neg. temperature range (14°F / ‐10°C)”
Start‐up temperature:
14°F to 104°F (-10°C to +40°C)
Operating temperature:
5°F to 104°F (-15°C to +40°C)
Ambient temperature with option “Extended temperature range”
Start‐up temperature:
-22°F to 122°F (-30°C to +50°C)
Operating temperature:
-22°F to 122°F (-30°C to +50°C)