12.1.2 Steps to close the Industrial PC
"
Before and while closing the device, for example after upgrades or servicing, check
that all seals are positioned correctly!
"
With S15P, S15R, S19P, S19R, S21WP, S21WR with enclosure variant Hygienic:
Check the correct position of the rubber seal and the special screw seal!
Apply the rubber seal first on the corners of the rear cover and then continue to the
middle of the edges.
Fig. 76: Correct position of seal
Fig. 77: Wrong position of seal
"
Put the rear cover back on the IPC front and fix in place using the screws removed
from the enclosure previously. Observe the tightening torques applicable to the
various screws. (See Chapter 8.2.)
Warning
For devices with internal power supply, after working near the internal power supply, a
routine safety test according DIN VDE 0701‐0702 have to be done!
12.2
Handling components
Warning
The Industrial PC contains electronic components with highly integrated modules or
modular elements. Due to the technology employed, these electronic components are
extremely sensitive to surges as well as to discharges of static electricity.
When working on and with electronic parts and components, follow the generally
applicable ESD guidelines.
As a general rule, noax recommends first touching a metal part, such as the system
carrier plate or connector plate, followed by the electronic part or component.
Warning
Do not touch the golden contacts of the parts and components.