Error Messages
page 161
NF 650 - rev. 01 / 29.06.2020
#
Error message
Cause of failure
Troubleshooting
31
Hardware
Logic (3.3V) Voltages too high
or too low
(1) Ensure that the power supply is stable on the
mains side.
(2) Disconnect the transmitter from the mains for ten
minutes and then reconnect.
(3) Contact NIVUS Hotline (serial number and exact
error message required).
32
Hardware
Logic (1.8V) Voltages too high
or too low
(1) Ensure that the power supply is stable on the
mains side.
(2) Disconnect the transmitter from the mains for ten
minutes and then reconnect.
(3) Contact NIVUS Hotline (serial number and exact
error message required).
33
Hardware
DRAM
(0.9V)
Voltages too high
or too low
(1) Ensure that the power supply is stable on the
mains side.
(2) Disconnect the transmitter from the mains for ten
minutes and then reconnect.
(3) Contact NIVUS Hotline (serial number and exact
error message required).
34
Hardware
I²C
Communication
error in plug-in
cards
(1) Ensure that the power supply is stable on the
mains side.
(2) Disconnect the transmitter from the mains for ten
minutes and then reconnect.
(3) Contact NIVUS Hotline (serial number and exact
error message required).
35
Hardware
Slot Power-
down
Plug-in card was
restarted because
of too many errors
(defective)
Contact NIVUS Hotline (serial number and exact error
message required).
41
Internal
memory
Persistent
Memory error in
PseudoRam on
SD card
(1) Disconnect the transmitter from the mains for ten
minutes and then reconnect.
(2) Contact NIVUS Hotline (serial number and exact
error message required).
42
Internal
memory
Persistent
Backup
Memory error in
PseudoRam on
SD card
(1) Disconnect the transmitter from the mains for ten
minutes and then reconnect.
(2) Contact NIVUS Hotline (serial number and exact
error message required).
43
Internal
memory
Archive
Memory error in
archive system on
SD card
(1) Disconnect the transmitter from the mains for ten
minutes and then reconnect.
(2) Replace SD card with an equivalent one.
(3) Contact NIVUS Hotline (serial number and exact
error message required).
44
System
Reboot
Device was ma-
nually booted
(also update)
No action necessary, because no error
45
System
Hardfault
Restart after pro-
gram error
Contact NIVUS Hotline (serial number and exact error
message required).
46
System
Watchdog
Restart after pro-
gram error
Contact NIVUS Hotline (serial number and exact error
message required).
47
System
Bootloader
Bootloader error
Contact NIVUS Hotline (serial number and exact error
message required).