Attention: Do not disrupt the descaling program. Never use vinegar or vinegar-based agents, only
standard liquid products specifically recommended for automatic coffee machines.
Attention: Before starting the descaling program remove the filter from the water tank.
➔
Turn the rotary control to “MAINTENANCE” and press it.
➔
Turn the rotary control to “DESCALING SYSTEM” and press to confirm.
The display shows “EMPTY TRAYS”.
➔
Remove drip tray with used coffee container (fig. 1/N and 1/O), and empty both.
➔
Reinsert drip tray and used coffee container.
The display shows “REMOVE WATER TANK”.
➔
Remove the water tank
The display shows “FILL WATER TANK TO 0,5l MARK” and “INSERT DESCALER TO TANK” alternat-
ingly.
➔
Remove the filter. Fill the water tank to the 0,5 l mark with fresh water and reinsert it.
Attention: Always add the water first to the 0,5 l mark and then the descaling agent. Never vice versa!
Please follow the manufacturer’s advice how to use the descaler.
➔
Only now add the descaler.
The display shows “CONNECT HOSE TO SPOUT AND DRIP TRAY”.
➔
Connect one end of the hose to the spout (fig. 7).
➔
Connect the other end to the drip tray (fig. 10).
➔
Press the rotary control.
The display shows “START DESCALING”.
➔
Place a sufficiently large bowl (minimum contents 0.5 l) under the spout (fig. 1/E).
➔
Press the rotary control.
The descaling process starts. The display shows “SYSTEM DESCALING”. The descaling process is
automatic and takes approximately 30 minutes. The descaling solution is transported through the
system in intervals.
Once the cycle is completed, the display shows “EMPTY TRAYS”.
➔
Remove drip tray with used coffee container (fig. 1/N and 1/O) and empty both.
➔
Reinsert drip tray and used coffee container.
➔
Remove water tank and rinse it with fresh water.
➔
Reinsert filter in the water tank if required.
➔
Fill the water tank with fresh water and reinsert it.
The display shows “CONNECT HOSE TO SPOUT AND DRIP TRAY”.
➔
Connect the hose with one end to the spout (fig. 7).
➔
Connect the other end to the drip tray (fig. 10).
➔
Place a sufficiently large bowl (about 0.5 l) under the spout.
➔
Press the rotary control.
The display shows “PLEASE RINSE”.
➔
Press the rotary control to start rinsing process.
The display shows “SYSTEM RINSING, DO NOT REMOVE HOSE”. The automatic cleaning process
is started that lasts for approximately two minutes. Once the cycle is finished, the display shows
“EMPTY TRAYS”.
➔
Empty drip tray and used coffee container (fig. 1/N and 1/O) and reinsert both.
The appliance reheats and is ready for use. The display shows the main menu.
85
GB
5. Cleaning and maintenance
04_Niv_859_BDA_sw_GB_03.indd 85
13.04.17 15:42