-42-
6.
Maintenance
Caution
Be sure to disconnect power before carrying out any maintenance work.
Use the specified screws. When fixing, tighten the screw with the recommended tightening torque. Insufficient
tightening may result in damage, falling, or failure to achieve the designated protection performance.
Excessive tightening may damage the product.
※
The proper tightening torque means
the torque at the completion of
tightening,and does not during
tightening process.
Kind of screw
Proper tightening torque value
N·m
※
Front panel fixing screw M4×8
0.7~1.2
External
fan
fixing screw M4×45
0.7~1.2
ground screw M4×6
0.7~1.2
Internal
fan
mounting plate
fixing screw 4×8
1.1~1.6
fixing screw M4×50
0.6~1.1
fixing nut M4
When replacing the fan, please wear gloves and other protective equipment.
→Contact with parts inside the product such as evaporator (aluminum fan) may cause injury.
Use the specified filter for replacement. Use of fine filters will cause efficiency loss in heat releasing which leads
to reduced cooling performance and/or breakdown of the unit.
Cleaning and user maintenance shall not be made by children.
The appliance shall not be cleaned with a water jet.
The cooling circuit of Compressor Cooler has been filled with a required
amount of refrigerant, tested for leaks and subject to a trial run before
delivery.
Therefore, there is no need of maintenance for the circuit.
The durability of Compressor Cooler is generally 30,000 operating hours,
provided that its filter is kept clean. Depending on the environmental
condition at the site of use, check and clean the filter, if used, at least once a
week.
Clogging on filter may lead to deterioration in cooling performance, or at
worst, may cause shutdown of the unit due to overloading on the compressor.
6-1
Filter cleaning/replacement
Detach the filter from the guide of the front panel to clean or replace.
◎
Replacement filter for external suction port
Model
Applicable Compressor Cooler models
PCN-F1
PCN-30-2
、
60-2
PCN-F2
PCN-100-2
PCN-F3
PCN-160-2
6-2
Replacement of the external fan (Ex. PCN-60-2)
Fan replacement procedures are as follows.
①
Turn off the Compressor Cooler.
②
Unscrew the front panel fixing screw M4
×8
of front panel to remove.
③
Unscrew the fixing screw M4×45 fixing the fan as shown in the right.
④
Remove the electric cord, earth wire and the insulation rubber of fan
terminals and then detach the fan to replace.
⑤
Attach a new fan in the reverse order to the above.
・
Pay attention not to get the cable caught in.
・
Put the insulation rubber on the fan terminals without fail.
6-3
Replacement of the internal fan (Ex. PCN-60-2)
①
Turn off the Compressor Cooler.
②
Remove the mounting plate fixing screw 4
×8
as shown in the right.
③
Remove the fan mounting plate.
④
Remove the fan cord to replace the fan” fixed screws M4×50 and nuts M4”.
⑤
Insert the fan cord and reattach the mounting place in thereverse
process.
・
Pay attention not to tuck the fan cord.
External fan
Condenser
Fixing screw M4×45
Mounting plate fixing
screw M4×8
Internal Fan
mounting plate
Fixing screw M4×50
Fixing nut M4
Filter (White)