F
NEPTUNE PE-DE_en_Ver.1.0_October 2010
Service / Repair
61
Electrodes
6mm
4 mm
5 mm
Spring washer
The electrode is adjusted from factory.
If the distance between the legs beco-
mes greater than 4 mm, the electrode
must be changed.
The electrode 18 is self adjusting the
position on the nozzle by a spring
washer 19 under the fixing screw 20.
7
6
13
21
22
4
5
9
10
12
14
11
17
19
18
20
The flame sensor 9 must be fixed
with 5 in the right position.
Clean the flame sensor
Burner Electrodes
Jetwash Direct ltd
Summary of Contents for NEPTUNE 5-46 PE
Page 1: ...Service Manual NEPTUNE PE DE NEPTUNE PE DE_en_Ver 1 0_October 2010 Jetwash Direct ltd...
Page 42: ...F NEPTUNE PE DE_en_Ver 1 0_October 2010 Service Repair 42 NA5 Pump Jetwash Direct ltd...
Page 48: ...F NEPTUNE PE DE_en_Ver 1 0_October 2010 Service Repair 48 C3 Pump Jetwash Direct ltd...
Page 93: ...93 NEPTUNE PE DE_en_Ver 1 0_October 2010 Notes Jetwash Direct ltd...
Page 94: ...JETWASH DIRECT LTD www jetwashdirect co uk sales jetwashdirect co uk Jetwash Direct ltd...