41
Fault
Cause
Remedy
Green
LED
does
not illuminate.
⇒
No power to microproc-
essor.
•
Make sure the machine
is plugged in.
•
Operate main switch S1.
•
Check the primary and
secondary voltage (8
Vac) on transformer T1.
•
Pico fuse F1 has blown
(self-resetting). Wait un-
til F1 is reset or, if the
fault persists, replace
electronic controller A1
(Chapter F.8.1).
Pressure too low.
⇒
HP nozzle worn.
⇒
Pressure rate control or
Vario Press set for too
low a pressure.
⇒
Flexo Power nozzle
open.
•
Replace the HP nozzle.
•
Turn the pressure rate
control on the unloader
valve in the direction
"+", or set the Vario
Press rotary knob
(accessory) on the pistol
for a larger amount of
water.
•
Close the Flexo Power
nozzle.
Machine runs jerk-
ily.
⇒
HP pump taking air in
from empty detergent
tank
•
Close the detergent dos-
ing valve. Take the
spray pipe off the spray
pistol. Operate the spray
pistol and let the ma-
chine run until the air is
expelled from the sys-
tem and the pump works
smoothly.
Jetwash Direct ltd
Summary of Contents for NEPTUNE 5-46 PE
Page 1: ...Service Manual NEPTUNE PE DE NEPTUNE PE DE_en_Ver 1 0_October 2010 Jetwash Direct ltd...
Page 42: ...F NEPTUNE PE DE_en_Ver 1 0_October 2010 Service Repair 42 NA5 Pump Jetwash Direct ltd...
Page 48: ...F NEPTUNE PE DE_en_Ver 1 0_October 2010 Service Repair 48 C3 Pump Jetwash Direct ltd...
Page 93: ...93 NEPTUNE PE DE_en_Ver 1 0_October 2010 Notes Jetwash Direct ltd...
Page 94: ...JETWASH DIRECT LTD www jetwashdirect co uk sales jetwashdirect co uk Jetwash Direct ltd...