D
26
NEPTUNE PE-DE_en_Ver.1.0_October 2010
Function
Functional desription of Circuit Board, A1—Continued
The flame sensor B7 is controlling if the fuel is ignited, and if it is (the flame sensor can see the
flame) it “allows” the burner to burn.
If the flame sensor don’t see the flame after 4 sec. (when S1 is in hot water mode), the fuel solenoid
valve will close, and the burner will be stopped.
If the display is flashing in the LED’s, it can be due to too low RPM on the motor.
If the LED’s are flashing, it means that the voltage is too low to maintain the circuit board.
The flashing LED’s means that the display is “re-starting” all the time.
Jetwash Direct ltd
Summary of Contents for NEPTUNE 5-46 PE
Page 1: ...Service Manual NEPTUNE PE DE NEPTUNE PE DE_en_Ver 1 0_October 2010 Jetwash Direct ltd...
Page 42: ...F NEPTUNE PE DE_en_Ver 1 0_October 2010 Service Repair 42 NA5 Pump Jetwash Direct ltd...
Page 48: ...F NEPTUNE PE DE_en_Ver 1 0_October 2010 Service Repair 48 C3 Pump Jetwash Direct ltd...
Page 93: ...93 NEPTUNE PE DE_en_Ver 1 0_October 2010 Notes Jetwash Direct ltd...
Page 94: ...JETWASH DIRECT LTD www jetwashdirect co uk sales jetwashdirect co uk Jetwash Direct ltd...