Fault
Cause
Remedy
Green
LED
flas-
hes.
⇒
Flow sensor fault.
⇒
Water tap closed or wa-
ter flow inadequate.
⇒
Detergent tank empty.
⇒
Pressure rate control or
Vario Press set for too
small amount of water.
⇒
Machine scaled up.
•
See Chapter F.3.3,
F.3.5 and G.3.4."Cold
water" mode is possible.
•
Requirements in Chap-
ter B.
•
Refill detergent or set
the SDR valve to "0".
•
Set the pressure rate
control or Vario Press
for a higher water flow.
•
Descale the machine.
Green
LED
and
red
LED
flash si-
multaneously.
⇒
Leakage or impermissi-
ble operating status
through brief operation.
⇒
Spray pistol leaking.
⇒
HP hose, HP coupling or
pipe leaking.
⇒
Detergent tank empty.
⇒
Filter clogged in water
intake.
⇒
HP pump sucking in air.
•
The machine cuts out
after being briefly oper-
ated three times.
Reset:
set the main switch to
"Off". Operate the pistol
for > 3 s.
•
Check the spray pistol.
•
Tighten the screws, re-
place the HP hose or
pipe.
•
Refill detergent.
•
Clean the filter
•
Correct leaking points.
Jetwash Direct ltd
Summary of Contents for NEPTUNE 5-46 PE
Page 1: ...Service Manual NEPTUNE PE DE NEPTUNE PE DE_en_Ver 1 0_October 2010 Jetwash Direct ltd...
Page 42: ...F NEPTUNE PE DE_en_Ver 1 0_October 2010 Service Repair 42 NA5 Pump Jetwash Direct ltd...
Page 48: ...F NEPTUNE PE DE_en_Ver 1 0_October 2010 Service Repair 48 C3 Pump Jetwash Direct ltd...
Page 93: ...93 NEPTUNE PE DE_en_Ver 1 0_October 2010 Notes Jetwash Direct ltd...
Page 94: ...JETWASH DIRECT LTD www jetwashdirect co uk sales jetwashdirect co uk Jetwash Direct ltd...