Control System
44
Service Manual – Scrubtec R 253 - RA40
Shop Measurements
The following tables contain some “real world” shop voltage measurements to help you recognize what “nor-
mal” looks like. All voltage values were measured with the black (Negative) voltmeter lead connected to the
main battery negative unless otherwise specified.
Shop Measurements - Function Electronic Board (EB1)
Battery volts at battery, key on = 24.55V (23.5V Vac on high).
Power Supply
Figure 32
PIN
Color
Description
Measured
Comments
B+
Red
Electronic board power
23.4V
Measured B+ to B-, Vac on high
B-
Black
Electronic board power supply -
23.4V
Measured B+ to B-, Vac on high
Brush Motor
Figure 33
PIN
Color
Description
Measured
Comments
BR+
Red
Brush motor +
23.5V
Measured to BR-, normal scrub
BR-
Blue
Brush motor -
23.5V
Measured to BR+, normal scrub
https://harrissupplyind.com - To Order Parts Call 608-268-8080