![Nilfisk-Advance R 253 9087362020 Service Manual Download Page 74](http://html.mh-extra.com/html/nilfisk-advance/r-253-9087362020/r-253-9087362020_service-manual_1693304074.webp)
Recovery System
74
Service Manual – Scrubtec R 253 - RA40
Removal and Installation
Vacuum System Motor Unit Disassembly/Assembly
Disassembly
1 Remove the operator key
2 Disconnect the red battery connector
3 If present, drain the recovery tank, then lift it
4 Disconnect the connector (A) (Figure 6) and remove the fastening clamp
5 Unscrew the 3 screws (B) and remove the vacuum system motor unit (C)
Figure 6
B
B
C
B
A
Assembly
6 Assemble the components in the reverse order of disassembly