Wheels, Drive System 123
Service Manual – Scrubtec R 253 - RA40
Removal and Installation
Drive Pedal Potentiometer Disassembly/Assembly
Disassembly
1
Drive the machine on a level floor or on a hoisting system to facilitate the disassembly procedures.
2 Remove the operator key and disconnect the red battery connector
3 Lift the machine as shown (A, Figure 5)
4 Remove the 2 screws (B) and disassemble the accelerator pedal (C)
5 Under the machine disconnect the connection (D) of the drive pedal potentiometer (E)
6 Remove the 3 screws (F), then disassemble the drive pedal potentiometer (E)
Figure 5
C
F
A
B
E
E
D
Assembly
7 Assemble the components in the reverse order of disassembly