10
110007944-EN
Software Manual_Pegasus.
C6 Low Sensor
Supply Voltage
1. Voltage supply for sensors too low
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C7 No Response
Error
1. No communication between display and control
board
1. Contact your local service technician.
C8 Low Tank
Level
1. Insufficient water supply
2. Water supply valve not open
1. Check correct water supply
2. Secure suffcient air supply to valve
3. Contact your local service technician.
C9 High Tank
Level
1. Water supply valve not closed
1. Secure sufficient air supply to the
valve.
2. Contact your local service technician.
C11 Warning
Cri. Inlet press.
1. Insufficient water supply
2. Booster will return to standby mode after 20 sec.
If this error occurs 3 times within 20 min. Error C2
occurs.
1. Secure suffcient water supply or re
-
duce consumption
2. Check inlet filter for impurities/rinse
filter
3. Contact your local service technician.
C13 Warning
Low inlet press.
1. Insufficient water supply.
The machine will keep on working as always, but the
maximum speed of the pump will be reduced until suf-
ficient inlet pressure is present.
1. Secure sufficient water supply or
reduce consuption
2. Check inelt filter for impurities/Rinse
filter
C14 Warning
leakage start
1. Booster start condition changed to flow, due to
leakage in pipe
1. Check for leakage in pipe system.
2. Press “off” button
3. If error reoccurs, contact your local
service technician.
C20 Low Sensor
Signal P-Pump-
top
1. Pressure signal from pumptop sensor, out of range 1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C21 Low Sensor
Signal T-Pump-
top
1. Temparature signal from pumptop, sensor, out of
range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C22 Low Sensor
Signal P-Inlet
1. Pressure signal form inlet sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C23 Low Sensor
Signal T-Inlet
1. Temperature signal from inlet sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C24 Low Sensor
Signal block
1. Signal from block sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C25 Low Sensor
Signal flow
1. Signal from flow sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C30 High Sensor
Signal P-Puump-
top
1. Pressure signal from pumptop sensor, out of range 1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C31 High Sensor
Signal T-Pump-
top
1. Temperature signal from pumptop sensor, out of
range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C32 High Sensor
Signal P-Inlet
1. Pressure signal from inlet sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C33 High Sensor
Signal T-Inlet
1. Temperature signal from inlet sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.