9
110007944-EN
Software Manual_Pegasus.
5.1 Content of the Info menu
Please note that the Info menu is only for display – all data must be typed in via the setup menu!
Info
i
A
INFO
HW ID:PEGASUS
CT ID:
AEA
SW ID: 5.02 5-14
1.01
This display view is only ment as an example, SW ID and
CT ID shows the current SW version.
Displays Software version and Pump size, machine
configuration and controller software version/ID.
5.2 Content of the Errors menu – CAUSE & REMEDY
Example of Error log screen display:
All error occurrences will be stamped with date and time.
E indicates Error number. P indicates Pump number.
E0\P1
2006-01-01
12:00
C1 Inverter
Error
BA
E0\P1
2006-01-01
12:00
C1 Inverter
Error
BA
The error log stores up to 1000 occurrences. When max. memory is reached, the errors will be
deleted according to ”First in” First out” principle.
5.2.1 Error List
Error
Cause
Remedy
C1 Inverter
Error
1. Frequency inverter in error state
1. Switch off the power on the service
switch. Wait 180 sec. Switch on the unit
again. If error still occurs, please contact
your local service technician.
C2 Low Supply
Pressure
1. Insufficient water supply
1. Secure sufficient water supply pres
-
sure.
2. Check inlet filter for impurities/rinse
filter
3. Contact your local service technician.
C3 High Water
Temp.
1. Water pump top temperature is above 80°
2. Water consumption is too low (pump column has
been overheated)
1. Lower the inlet water temp. (max
70°C)
2. Secure sufficient water consumption
3. Contact your local service technician.
C4 High Motor
Temp.
1. Insufficient cooling of motor
2. The ambient temperature is above 40°
1. Secure that all air channels are open
and not blocked by impurities
2. Lower ambient temperature
C5 High Supply
Temp.
1. Water inlet temperature is above 70°
1. Lower the water temp. (max 70°C)
2. Contact your local service technician.