60
60
60
60
60 - FORM NO. 56043089 / AquaRide
™
/ BRX 700
ELECTRICAL SYSTEM
ELECTRICAL SYSTEM
ELECTRICAL SYSTEM
ELECTRICAL SYSTEM
ELECTRICAL SYSTEM
The MORE INFO key, when used in the Program mode, displays a bar graph along with the minimum and maximum values possible
for the selected parameter. Parameters can be changed either from the main Program Menu or after the MORE INFO key has been
pressed and the additional information is being displayed.
1228 PROGRAM MENU
1228 PROGRAM MENU
1228 PROGRAM MENU
1228 PROGRAM MENU
1228 PROGRAM MENU
ACCEL MAX SPD
Acceleration rate at maximum throttle requests, in seconds
ACCEL MIN SPD
Acceleration rate at minimum throttle requests, in seconds
REV ACCEL MAX
Reverse accel rate at maximum throttle requests, in seconds
REV ACCEL MIN
Reverse accel rate at minimum throttle requests, in seconds
REV DECEL MIN
Reverse decel rate at minimum throttle requests, in seconds
M1 MAX SPD
Mode 1 max. speed with speed pot at max, as % available
M2 MAX SPD
Mode 2 max. speed with speed pot at max, as % available
M1 MIN SPD
Mode 1 max. speed with speed pot at min, as % available
M2 MIN SPD
Mode 2 max. speed with speed pot at min, as % available
M1 REV MAX SPD
Mode 1 max. reverse speed with speed pot at max, as % available
M2 REV MAX SPD
Mode 2 max. reverse speed with speed pot at max, as % available
THRTL AUTOCAL
Wigwag throttle centering utility: On/Off
TEST MODE
TEST MODE
TEST MODE
TEST MODE
TEST MODE
In the Test
Test
Test
Test
Test mode, accessed by pressing the TEST key, real-time information is
displayed about the status of the inputs, outputs, and controller temperature. For
example, when the status of the forward switch is displayed, it should read “On/Off/
On/Off/On/Off’ as the switch is repeatedly turned on and off. In the Test mode, the
item of interest does not need to be the top item on the list; it only needs to be among
the four items visible in the window. The Test mode is useful for checking out the
operation of the controller during initial installation, and also for troubleshooting
should problems occur.
The MORE INFO key, when used in the Test mode, causes additional information to
be displayed about the selected item (top line in the window).
1228 TEST MENU
1228 TEST MENU
1228 TEST MENU
1228 TEST MENU
1228 TEST MENU
HEAT SINK TEMP
Heatsink temperature, in °C
THROTTLE %
Throttle request: 0–100% of range
SPD LIMIT POT
Speed limit pot rotation: 0–100%
BATT VOLTAGE
Battery voltage across the capacitors
MODE INPUT A
On = Mode 1; Off = Mode 2
REVERSE INPUT
On = reverse is selected
INHIBIT IN
On = operation is inhibited
EM BRAKE DRVR
On = electromagnetic brake is mechanically released
MAIN CONT
On = voltage is applied to main relay coil
MOTOR R
Cold motor resistance, in mOhms
PUSH ENABLE IN
On = push enable switch is closed
OPERA
OPERA
OPERA
OPERA
OPERATING MODES (CONTINUED)
TING MODES (CONTINUED)
TING MODES (CONTINUED)
TING MODES (CONTINUED)
TING MODES (CONTINUED)
TEST
TEST
TEST
TEST
TEST