background image

16-661-01 / 16-660-01 / 16-660-02

8

Read the complete manual before attempting installation and activating the system.

1. DESCRIPTION

The 16-661-01 is a video internal unit and is part of the range Access Control Design. This appliance can display a color image of your visitor while you 
are talking to him/her. The 16-661-01 video internal unit is suitable for surface mounting on a wall (as a standard). It can also be used as a freestanding 
appliance. You can adjust the angle of inclination by means of the supplied base (16-660-01). The video internal unit can also be partially flush mounted 
in the wall by means of a special mounting box (16-660-02). The video internal unit 16-661-01 is powered via the UTP cable of the system. The internal 
unit is provided with a flat color LCD display.

2. INSTALLATION

2.1. Check whether you have the following components at your disposal:

- Video internal unit 16-661-01
- UTP cable, CAT.5E (from the video splitter or switcher to the video internal unit) with RJ45 connectors at both sides.
The UTP cable connects the 16-661-01 to the video splitter or switcher (max. 100m).
This UTP cable (CAT.5E) contains the cores for connection to the power supply, the analog telephone line, the video signal and a bus.

Color code UTP cable: 
  1. orange-white 

1. Vsup (+)

  2. orange 

2. Ground (-)

  3. green-white 

3. bus H

  4. blue 

4. telephony (tip)

  5. blue-white 

5. telephony (ring)

  6. green 

6. bus L

  7. brown-white 

7. video+

  8. brown 

8. video-

4 TEL tip
5 TEL ring

7 VIDEO +

8 VIDEO -

1 + Vsup
2 - Gnd
3 Bus H

6 Bus L

Attention! 

Wrong  cabling  can 

severely  damage  the 

products in an instal-

lation!

2.2. Installation as surface mounting appliance

Mount the video internal unit 16-661-01 on the wall as shown in fig.1. Provide a standard flush mounting box at the indicated place.

2.3. Installation as flush mounting appliance

Mount the video internal unit 16-661-01 as shown in fig. 2, 3 and 4. Provide a standard flush mounting box behind the flush mounting frame (16-660-02) 
at the indicated place. Then mount the flush mounting frame on the flush mounting box. The opening in the wall must have the following dimensions: L221 
x W188 x D21mm.

Attention: 

Take into account the depth of the flush mounting frame when placing the standard flush mounting box. 

2.4. Installation as a freestanding appliance on a base (16-660-01)

Mount the base as in fig. 5. Choose the fixing points that enable to look at the display perpendicularly.

3. PROGRAMMING

Via the interface, you enter the system’s programming or reset mode. 
For an exhaustive description of the programming, see user manual of the 16-651.

The 16-661-01 or internal unit gives feedback during programming. Pick up the receiver.
- in programming mode:
 

* 5 beeps: address saved.

 

* no beep: address had already been saved.

- in reset mode:
 

* 5 beeps: internal unit reset.

 

* no beep: internal unit had already been reset.

4. OPERATION AND USE

If the installation has been programmed correctly, the display of the right internal unit(s) lights if the bell is rung. You can see your visitor without picking up 
the receiver, even if the call is rerouted (audio and video are programmed seperately). The display is activated for as long as the call lasts.

4.1. Answering a call

If the call is actually rerouted to the appliance, this appliance rings. Pick up the receiver to talk to your visitor. You can control the electric locks during the 
conversation. Press key 1 or 2 (depending on the lock you wish to control) (see user manual 16-651). Press 

 to end the conversation.

4.2. Activating an external unit (image and communication)

You can activate the external unit without the bell being rung. For this purpose, make a call to the electronic control unit 16-651 via the telephone exchange 
and switch on the door telephone (key 3). Camera, loudspeaker and microphone are activated. If you have connected and programmed several door units/
cameras on the video internal unit 16-661-01 concerned, you can run through the camera images one by one. Repeatedly press key 3. Press 

 to end 

the conversation.

4.3. Telephone functions  

You can use the appliance as an ordinary, analog telephone with all the functions the analog line of the connected telephone exchange offers. The telephone 
is provided with a magnetic receiver contact that is activated if the receiver is held close to the telephone.

EN

Summary of Contents for 16-660-01

Page 1: ...hter het inbouwraam 16 660 02 op de aangegeven plaats Monteer vervolgens het inbouwraam boven de inbouwdoos De opening in de wand moet de volgende afmetingen hebben L221 x B188 x D21mm Let wel Hou rek...

Page 2: ...smiddelen die een oplosmiddel of een zuur bevatten of schoonmaakmiddelen met azijnzuur 7 WETTELIJKE WAARSCHUWINGEN De installatie dient te worden uitgevoerd door een erkend installateur en met inachtn...

Page 3: ...t indiqu Montez ensuite le support encastrer au dessus de la bo te d encastrement L ouverture dans le mur doit avoir les dimensions suivantes L221 x l188 x P21mm Attention tenez compte de la profondeu...

Page 4: ...peu de savon suffit L utilisation des produits suivants est strictement d conseill e ponges abrasives ou d tergents abrasifs produits d entretien contenant un solvant ou un acide ou l acide ac tique...

Page 5: ...lgenden Abmessungen haben L221 x B188 x T21mm Achtung Man beachte die Tiefe des Einbaurahmens um die Standard UP Dose zu setzen 2 4 Montage als frei aufstellbares Ger t mit Fu 16 660 01 Zuerst wird de...

Page 6: ...ss an eine private Nebenstellenanlage Entspricht der Richtlinie TBR 21 Tonwahlverfahren DTMF 6 PRODUKTPFLEGE Anhand der nachfolgenden Pflegetips soll vermieden werden dass die Oberfl che dieser Luxusp...

Page 7: ...kunde das Recht auf eine kostenlose Reparatur oder Ersatz Dies wird von Niko entschieden Niko ist nicht f r einen Mangel oder Schaden verantwortlich der durch unsachgem e Installation nicht bestimmung...

Page 8: ...he opening in the wall must have the following dimensions L221 x W188 x D21mm Attention Take into account the depth of the flush mounting frame when placing the standard flush mounting box 2 4 Install...

Page 9: ...ining acetic acid 7 LEGAL WARNINGS The installation has to be carried out by a qualified person and in compliance with the statutory regulations This user manual has to be handed over to the user It h...

Page 10: ...otrar 16 660 02 en el lugar indicado A continuaci n monte el soporte de empotrar por encima de la caja de empotrar La apertura en el muro tendr que tener las dimen siones siguientes Largo 221 x ancho...

Page 11: ...a o h medo y un poco de jab n Est estrictamente desaconsejado utilizar los productos siguientes esponjas abrasivas o detergentes abrasivos productos de mantenimiento que contengan un disolvente un cid...

Page 12: ...ene mus ma nasledovn rozmery D221 x 188 x H21mm Pozor Pri umiest ovan tandardnej zapustenej mont nej katule berte do vahy aj h bku zapusten ho mont neho r mu 2 4 In tal cia vo ne stojaceho zariadenie...

Page 13: ...OZORNENIA Pred in tal ciou a spusten m syst mu si pre tajte cel pr ru ku In tal ciu mus vykona autorizovan opr vnen pracovn k a mus by v s lade so z konn mi predpismi a normami T to u vate sk pr ru ka...

Page 14: ...6 135 20 31 46 135 158 2 1 fig 1 Connectors internal unit Connection box for flush mounting in the wall min 30mm Fixing points for surface mounting the internal unit fig 2 235 190 202 13 1 14 5 160 14...

Page 15: ...16 661 01 16 660 01 16 660 02 15 fig 3 fig 4 fig 5...

Page 16: ...16 661 01 16 660 01 16 660 02 16 nv Niko sa Industriepark West 40 BE 9100 Sint Niklaas tel 32 0 3 778 90 00 fax 32 0 3 777 71 20 e mail support niko be www niko be PM016 66101R08103...

Reviews: