Note: This appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2 psig
(3.45 kPa).
Note: This appliance must be isolated from the gas supply piping system by closing its individ-
ual manual shutoff valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.45 kPa).
In Canada, installation shall be in accordance with CAN/CGA-B149.1 Natural Gas or CAN/CGA-B149.2
Propane Gas, and local codes where applicable.
By public initiative, the State of California has adopted legislation (Proposition 65) which requires manu-
facturers of many types of products, including gas appliances, to warn consumers of their products that
contain chemicals or produce substances listed by the State of California to either cause cancer, birth
defects, or other reproductive harm.
WARNING: If not installed, operated, and maintained in accordance with the manufacturer's
instructions, this product could expose you to substances in fuel, or from fuel combustion which
can cause cancer, birth defects, or other reproductive harm.
ELECTRICAL CONNECTION
Power requirements are stated on the unit nameplate and must be connected accordingly. Before start-
ing broiler, tighten all electrical connections in control box. An electrical diagram is located inside the
control box.
Note: This appliance must be electrically grounded in accordance with local codes or in the
absence of local codes, the National Electrical Code, ANSI/NFPA No. 70-1990. In Canada, in
accordance with the Canadian Electrical Code CSA 22.1 part 1, or local codes.
WARNING: This appliance should be connected with a four-pronged grounding plug for
your protection against shock hazard. Be sure to plug directly into a properly grounded
four-prong receptacle. Do not cut or remove grounding prong from plug.
Note: This appliance cannot be safely operated in the event of a power failure. No attempt
should be made to operate during a power failure. Disconnect power supply before servicing.
PRE-OPERATION CHECK
Be sure that all parts are installed in the proper location. Refer to OPERATION section for lighting proce-
dure. Start broiler and test for proper operation.
Summary of Contents for 940 Gas
Page 2: ......
Page 14: ...14 D PARTS AND LOCATION 940 AND 960 GAS...
Page 15: ...15 D PARTS AND LOCATION 940 AND 960 GAS...
Page 16: ...16 D PARTS AND LOCATION 940 AND 960 GAS...
Page 25: ...25 WIRING DIAGRAM Models 940 960 Gas DOMESTIC...
Page 26: ...26 WIRING DIAGRAM Models 940 960 Gas EXPORT...
Page 27: ...27 NOTES...