background image

1

1. Installation to the Start of Operation

2. Unit Model

3. Specifications

4. Component Part Names and Functions

5. External Dimensions

6. Installation to the Panel

7. Wiring to Power Source and Sensors (DT-501XA/DT-501XD)

8. Wiring to Power Source and Sensors (DT-501FA)

9. Basic Setting Procedure

10. Keys to be Used for Various Settings and Their Applications

11. Teaching Function Settings

12. About Mode

13. When You Select Mode 1 (Digital Tachometer Mode) for Measurement

14. When You Select Mode 2 (Elapsed Timecounter Mode) for Measurement

15. When You Select Mode 3 (Time Width Meter Mode) for Measurement

16. When You Select Mode 4 (Flowmeter Mode) for Measurement

17. Setting Method of Functions (Excluding in the Test Mode, Common in Each Mode)

18. Comparator Function

19. Memory Function

20. Test Mode (Function to Check if the Unit is Operating Normally)

21. Error Display

22. Parameter List

23. Function List

24. Option   -FVT/-FVC

25. Option  -BCD

26. Option  -TRT

27. Option  -CPT

28. DT-501X / DT-501F series model list

CAUTION

Precautions before use

Power

●Be sure to use the unit under the specified voltage (AC power 
  specifications: 85 - 264VAC / DC power specifications: 10.8 - 25.2VDC).
●Inverter power source cannot be used.

Input signal wire

●Connection wiring from sensors shall not be kept in the same or parallel conduit or 
  cable as the power source, power or high voltage cables. If you fail to separate the
  wiring, noise may be superimposed on the signal wire, resulting in malfunctions.
●Use shielded wire for input power connections with the shortest possible metal conduit.

Terminal

●Check that the screws have not come loose due to vibrations after a certain period of time.

Operating environment

●Do not install the unit in the following places or conditions.
● ● Places exposed to direct sunlight, or places where the ambient temperature 
      exceeds a range of 0 - 45ºC.
● ● Places where the relative humidity percentage exceeds a range of 35 - 85%, or
      places subject to condensation due to rapid change in humidity.
● ● Places subject to corrosive and/or combustible gases.
● ● Places subject to a large amount of dust, salinity, and/or ferric substance.
● ● Places susceptible to noise (including static electricity).

98211B

!

!

INDEX

Digital Tachometer

2
2
3
3
4
4
5
6
6
6
7
8
8
10
12
14
16
17
18
19
19
20
21
23
25
27
27
28

After reading, be sure to store this manual in a safe, 

convenient place where operators can always refer to it easily.

Thank you for purchasing SHIMPO's Digital Tachometer DT-501X/ 

DT-501F. For instructions on how to use this product properly 

and optimally for a long period of time, please be sure to read this 

manual thoroughly before use.

When you purchase the product with optional equipment:

Please refer to the operation manual of the optional equipment.

Before operation, maintenance and inspection, please 

carefully read this instruction manual and follow it 

for proper use.

DT-501X/DT-501F

Standard input series

Differential input series

Instruction Manual

Digital Tachometer/ Elapsed timecounter/ Time width meter/ Flowmeter

Electric Shock.

Be sure to turn the power OFF when wiring as well as 

inspecting the unit.

DO NOT block the ventilation holes on the side of the main unit.

DO NOT put any foreign objects or materials inside the unit 

through these holes.

DO NOT touch the unit with wet (or sweaty) hands when 

inspecting or for wiring.

Failure to do so could result in electric shock.

Failure to follow this could result in abnormal heat generation 

and/or malfunctions.

Failure to do this could result in electric shock.

Before operation, maintenance and inspection, please carefully read this instruction 

manual and follow it for proper use. Please carefully read all information related to 

this unit and safety, and precautions before use.

● We are not responsible for damages resulting from negligence through failure to 

   follow the instructions set out in this manual.

● We are not responsible for damages resulting from earthquake and/or fire unrelated

   to us, actions by third parties, or any other accidents, intentional or through 

   customer negligence, as well as from accidents caused by misuse or improper use 

   under abnormal conditions.

● For information regarding assurance provisions, please read the attached warranty 

   certificate.

WARNING

Improper use may result in serious injuries.

CAUTION

Improper use may result in minor injuries or 

property damage.

DANGER

Improper use by neglecting the following 

precautions may result in the potential 

for fire, serious injuries, and/or death.

Safety Requirements

Be sure to observe

!

!

!

●Limited Warranty

This instruction manual categorizes safety precautions as “DANGER”, “WARNING”, 

and “CAUTION”.  Each of them is an important description related to safety. Be sure 

to observe.

www.calcert.com

[email protected]

1.888.610.7664

0

5

10

15

20

25

30

Summary of Contents for DT-501 FA-BCD

Page 1: ...reading be sure to store this manual in a safe convenient place where operators can always refer to it easily Thank you for purchasing SHIMPO s Digital Tachometer DT 501X DT 501F For instructions on...

Page 2: ...function settings p 17 19 Parameter settings p 8 15 Teaching function settings P7 1 Press the MEM key once to display the MAX value 2 Press the MEM key again to display the MIN value 3 Press the MEM...

Page 3: ...densation Operating humidity 35 85 RH No condensation Operating atmosphere No corrosive gas Conforming standard RoHS Protection function Front panel IP66 or equivalent Rear terminal block IP20 Casing...

Page 4: ...nt waterproofed but if water is splashed on the unit be sure to wipe it off the unit as soon as possible 1 Attach the provided waterproof gasket to the panel surface If waterproofing is not necessary...

Page 5: ...d on the signal wire resulting in malfunctions Use shielded wire for input power connections with the shortest possible metal conduit Terminal block connection diagram PWR1 PWR2 E PU OC RE MG GND 12V...

Page 6: ...nal connection Line driver Terminal block connection diagram Conduct the comparator function p 17 and memory function settings p 18 if necessary This unit requires no complicated calculation and imple...

Page 7: ...speed is outside the input revolution speed range EE 2 is displayed and the teaching function cannot be used When the input frequency is outside the input frequency range EE 2 is displayed and the tea...

Page 8: ...ted Circumference of the roller Revolution speed Normal display Mode setting Finish setting The main display shows 0 0 0 0 1 Press the SET key The display goes to mode 1 digital tachometer mode The nu...

Page 9: ...000000 999999 0 F2 Low set point 1 value Sets the high set point 1 value 000000 999999 0 F3 High set point 2 value Sets the high set point 2 value 000000 999999 0 F4 Low set point 2 value Sets the low...

Page 10: ...n Set each setting item for mode and parameter according to the following procedures For the setting method of functions refer to pages 16 and 17 As in the figure on the left bread passes through the...

Page 11: ...tops in the elapsed timecounter mode the display will overflow after the specified time set with the auto zero function The overflow display does not mean there is a malfunction When the input signal...

Page 12: ...em 0 00 00 0 00 0 00 1 100 sec 0 00 Select the 1 100 second display based on the operating time of the press machine P2 Measurement section 0 OFF 1 ON _ 1_ ON 0 Select 0 because the adjacent switch of...

Page 13: ...e low set point 1 value Hour Minute Second display system 0 00 00 9 59 59 Second display system 0 00 Sets the low set point 1 value Second display system 0 00 999 99 F3 High set point 2 value Sets the...

Page 14: ...ero time 0 1 150 sec _ _006 0 6 sec 6 sec Measure using the default setting value as no special instruction is provided P7 Input filter 10 30 100 0 02kHz _ 10_ 10kHz 10kHz Measure using the default se...

Page 15: ...Parameter 2 setting Parameter 3 setting Parameter 4 setting Parameter 5 setting Parameter 6 setting Parameter 7 setting Finish setting The main display shows 0 00 Press the ENT key and start setting...

Page 16: ...ost For the settings of the high set point 1 and 2 values as well as the low set point 1 and 2 values refer to Comparator Function on page 17 To the function settings The main display shows 0 0 0 1 F...

Page 17: ...t Conditions under the low set point 1 and 2 value judgment Judgment conditions Set the high set point 1 low set point 1 high set point 2 and low set point 2 values using the function items F01 to F04...

Page 18: ...y MAX MIN MAX MIN Normal measurement display Normal measurement display Normal measurement display Maximum value display Press the MEM key once during the normal measurement to display the maximum val...

Page 19: ...E 3 E E 4 BTM MAX MINTEA PEAK BTM Normal display LED display test Key test Version display Mode display Test mode Press and hold the SHIFT MODE keys for 5 seconds or more Press the key to change the m...

Page 20: ...er sensor blade cc etc Enter the capacity per blade that the sensor can read 0 0001 99999 1 0 P3 Scaling Unit coefficient value 0 00000 999999 1 P4 Decimal point display Designates the decimal point p...

Page 21: ...99 0 F6 Judgment output timer at startup 2 Sets the time when the comparator judgment is output at startup 0 99 sec 0 sec F7 Minimum revolution speed Sets the revolution speed to be displayed as zero...

Page 22: ...verage function is not set F8 setting value 0 When the auto zero function is activated the display becomes 0 in mode 2 and mode 3 Displays the measurement value per display cycle averaged by the frequ...

Page 23: ...ect one out of these output options 11 12 13 14 15 16 17 18 19 20 Code Pin number Code C 4 20mA 1 19 C 4 20mA 2 20 NC 3 21 NC NC 4 22 NC NC 5 23 NC NC 6 24 NC NC 7 25 NC NC 8 26 NC V10 0 10V 9 27 V10...

Page 24: ...log signal output offset Set the output offset value as the percentage of the output range for each analog signal __ 100 0 __100 0 0 4 20 mA 0 10 V 1 5 V 0 1 V Output range 16mA Output range 10V Outpu...

Page 25: ...r PCS E36LMD Accessory side Plug PCS E36FS Cover PCS E36LA Both manufactured by HONDA TSUSHIN KOGYO CO LTD Positive logic negative logic available for BCD and decimal point output opted at Function 10...

Page 26: ...output logic Set as 0 for negative logic set as 1 for positive logic decimal point output _ 0_ Negative logic _ 1_ Positive logic Negative logic F10 sets positive negative logic for BCD output Decima...

Page 27: ...c open collector output Model CPT Output contact 1C Rated load Resistance load 250VAC 5A 100K operations 30VDC 5A 100K operations Induction load cos 0 4 250VAC 2 5A 100K operations 30VDC 2 5A 100K ope...

Page 28: ...501XA BCD DT 501XD BCD BCD BCD output Differential input DT 501FA FVT FVT Voltage output DT 501FA FVT BCD BCD BCD output DT 501FA TRT TRT Transistor output DT 501FA TRT FVC FVC Voltage output DT 501FA...

Reviews: