background image

2

●1. 

Installation to the Start of Operation

●2. 

Unit Model

 

 Check before use

Please check the model number of the equipment purchased.

• Unit model

• Specifications

• Component part names and 

  functions

• External dimensions

Check before use

p.2 - 4

Installation to the panel

p.4

Connection with the

power and sensor

p.5 - 6

DT

501X
501F

Option #1

Option #2

Symbol

Output

Function

FVT

Analog Signal Output

Outputs voltage and current that correspond to displayed value

CPT

Relay Output

Relay Changeover contact output. H output, L output, and GO 

output, against the set value

TRT

Transistor Output

Open Collector Output. HH, H, LL, L GO and ZERO output.

Symbol

Output

Power Source

FVC

Analog Signal Output

Outputs voltage and current that correspond to displayed value

BCD

BCS Output

Open Collector, BCD Output

Simple interface with the sequencer

   

  *  HH : High set point 2 output

●●●●●H : High set point 1 output
●●●●●L :  Low set point 1 output
●●●● LL :  Low set point 2 output

This unit is designed for use according to your measurement purposes.

Before use, follow the procedures below from installation to the start of operation.

(1) Installation of waterproof gasket

(2) Fixation to the panel

View from

the front

Panel

(1) Connection with the power

(2) Connection with various sensors

View from 

the back

Connecting wires

Simple setting

●Parameter settings are not necessary.

Start of operation

Mode 

(function) 

settings 

p.8 - 15

Memory function

settings

p.17 - 19

Parameter settings

 

p.8 - 15

Teaching function settings

P7

(1) Press the MEM key once to

     display the MAX value.

(2) Press the MEM key again to

     display the MIN value.

(3) Press the MEM key once again 

     to display the normal measurement 

     value.

*You can use the unit without

  setting various functions.

(1) Press the SHIFT + MOD keys 

     and start setting.

(2) Use the 

s

 key to set, and use

 the SET key to finish setting.

(1) Press and hold the SHIFT +

     PAR keys for 5 seconds or 

     more and start setting.

(2) Press the 

key to select the

     item, and press the ENT key 

     to start changing the setting

     value.

(3) Press the        key to move to  

     another digit, and after 

     changing the value using the 

     ● key, use the ENT key to 

     finish the setting value  change.

(3) After setting all parameters, 

    use the SET key to finish setting.

(1) Press and hold the SHIFT + 

     FUNC  keys for 5 seconds or 

     more and start setting.

(2) Press the 

s

 key to select the

     item, and press the ENT key

     to start changing the setting

     value.

(3) Press the 

    

 key to move to

     another digit, and after

     changing the value using the

     

s

 key, use the ENT key to

     finish the setting value change.

(4) After setting all functions, use

     the SET key to finish setting.

Function 

(action configuration)

settings 

p.8 

p.16 -17

Input type

Symbol

Input type

501X

Standard input : Supports the sensor input, including rotary encoders, and magnetic sensors

501F(AC Power only) Differential input  Supports the line driver output, including AC servo motors

Power

Symbol

Power

A

AC power (85 - 264VAC)

D

DC power (10.8 - 25.2VDC)

t

t

www.calcert.com

[email protected]

1.888.610.7664

0

5

10

15

20

25

30

Summary of Contents for DT-501 FA-BCD

Page 1: ...reading be sure to store this manual in a safe convenient place where operators can always refer to it easily Thank you for purchasing SHIMPO s Digital Tachometer DT 501X DT 501F For instructions on...

Page 2: ...function settings p 17 19 Parameter settings p 8 15 Teaching function settings P7 1 Press the MEM key once to display the MAX value 2 Press the MEM key again to display the MIN value 3 Press the MEM...

Page 3: ...densation Operating humidity 35 85 RH No condensation Operating atmosphere No corrosive gas Conforming standard RoHS Protection function Front panel IP66 or equivalent Rear terminal block IP20 Casing...

Page 4: ...nt waterproofed but if water is splashed on the unit be sure to wipe it off the unit as soon as possible 1 Attach the provided waterproof gasket to the panel surface If waterproofing is not necessary...

Page 5: ...d on the signal wire resulting in malfunctions Use shielded wire for input power connections with the shortest possible metal conduit Terminal block connection diagram PWR1 PWR2 E PU OC RE MG GND 12V...

Page 6: ...nal connection Line driver Terminal block connection diagram Conduct the comparator function p 17 and memory function settings p 18 if necessary This unit requires no complicated calculation and imple...

Page 7: ...speed is outside the input revolution speed range EE 2 is displayed and the teaching function cannot be used When the input frequency is outside the input frequency range EE 2 is displayed and the tea...

Page 8: ...ted Circumference of the roller Revolution speed Normal display Mode setting Finish setting The main display shows 0 0 0 0 1 Press the SET key The display goes to mode 1 digital tachometer mode The nu...

Page 9: ...000000 999999 0 F2 Low set point 1 value Sets the high set point 1 value 000000 999999 0 F3 High set point 2 value Sets the high set point 2 value 000000 999999 0 F4 Low set point 2 value Sets the low...

Page 10: ...n Set each setting item for mode and parameter according to the following procedures For the setting method of functions refer to pages 16 and 17 As in the figure on the left bread passes through the...

Page 11: ...tops in the elapsed timecounter mode the display will overflow after the specified time set with the auto zero function The overflow display does not mean there is a malfunction When the input signal...

Page 12: ...em 0 00 00 0 00 0 00 1 100 sec 0 00 Select the 1 100 second display based on the operating time of the press machine P2 Measurement section 0 OFF 1 ON _ 1_ ON 0 Select 0 because the adjacent switch of...

Page 13: ...e low set point 1 value Hour Minute Second display system 0 00 00 9 59 59 Second display system 0 00 Sets the low set point 1 value Second display system 0 00 999 99 F3 High set point 2 value Sets the...

Page 14: ...ero time 0 1 150 sec _ _006 0 6 sec 6 sec Measure using the default setting value as no special instruction is provided P7 Input filter 10 30 100 0 02kHz _ 10_ 10kHz 10kHz Measure using the default se...

Page 15: ...Parameter 2 setting Parameter 3 setting Parameter 4 setting Parameter 5 setting Parameter 6 setting Parameter 7 setting Finish setting The main display shows 0 00 Press the ENT key and start setting...

Page 16: ...ost For the settings of the high set point 1 and 2 values as well as the low set point 1 and 2 values refer to Comparator Function on page 17 To the function settings The main display shows 0 0 0 1 F...

Page 17: ...t Conditions under the low set point 1 and 2 value judgment Judgment conditions Set the high set point 1 low set point 1 high set point 2 and low set point 2 values using the function items F01 to F04...

Page 18: ...y MAX MIN MAX MIN Normal measurement display Normal measurement display Normal measurement display Maximum value display Press the MEM key once during the normal measurement to display the maximum val...

Page 19: ...E 3 E E 4 BTM MAX MINTEA PEAK BTM Normal display LED display test Key test Version display Mode display Test mode Press and hold the SHIFT MODE keys for 5 seconds or more Press the key to change the m...

Page 20: ...er sensor blade cc etc Enter the capacity per blade that the sensor can read 0 0001 99999 1 0 P3 Scaling Unit coefficient value 0 00000 999999 1 P4 Decimal point display Designates the decimal point p...

Page 21: ...99 0 F6 Judgment output timer at startup 2 Sets the time when the comparator judgment is output at startup 0 99 sec 0 sec F7 Minimum revolution speed Sets the revolution speed to be displayed as zero...

Page 22: ...verage function is not set F8 setting value 0 When the auto zero function is activated the display becomes 0 in mode 2 and mode 3 Displays the measurement value per display cycle averaged by the frequ...

Page 23: ...ect one out of these output options 11 12 13 14 15 16 17 18 19 20 Code Pin number Code C 4 20mA 1 19 C 4 20mA 2 20 NC 3 21 NC NC 4 22 NC NC 5 23 NC NC 6 24 NC NC 7 25 NC NC 8 26 NC V10 0 10V 9 27 V10...

Page 24: ...log signal output offset Set the output offset value as the percentage of the output range for each analog signal __ 100 0 __100 0 0 4 20 mA 0 10 V 1 5 V 0 1 V Output range 16mA Output range 10V Outpu...

Page 25: ...r PCS E36LMD Accessory side Plug PCS E36FS Cover PCS E36LA Both manufactured by HONDA TSUSHIN KOGYO CO LTD Positive logic negative logic available for BCD and decimal point output opted at Function 10...

Page 26: ...output logic Set as 0 for negative logic set as 1 for positive logic decimal point output _ 0_ Negative logic _ 1_ Positive logic Negative logic F10 sets positive negative logic for BCD output Decima...

Page 27: ...c open collector output Model CPT Output contact 1C Rated load Resistance load 250VAC 5A 100K operations 30VDC 5A 100K operations Induction load cos 0 4 250VAC 2 5A 100K operations 30VDC 2 5A 100K ope...

Page 28: ...501XA BCD DT 501XD BCD BCD BCD output Differential input DT 501FA FVT FVT Voltage output DT 501FA FVT BCD BCD BCD output DT 501FA TRT TRT Transistor output DT 501FA TRT FVC FVC Voltage output DT 501FA...