●1.
Installation to the Start of Operation
●2.
Unit Model
Check before use
Please check the model number of the equipment purchased.
• Unit model
• Specifications
• Component part names and
functions
• External dimensions
Check before use
p.2 - 4
Installation to the panel
p.4
Connection with the
power and sensor
p.5 - 6
DT
501X
501F
Option #1
Option #2
Symbol
Output
Function
FVT
Analog Signal Output
Outputs voltage and current that correspond to displayed value
CPT
Relay Output
Relay Changeover contact output. H output, L output, and GO
output, against the set value
TRT
Transistor Output
Open Collector Output. HH, H, LL, L GO and ZERO output.
Symbol
Output
Power Source
FVC
Analog Signal Output
Outputs voltage and current that correspond to displayed value
BCD
BCS Output
Open Collector, BCD Output
Simple interface with the sequencer
* HH : High set point 2 output
●●●●●H : High set point 1 output
●●●●●L : Low set point 1 output
●●●● LL : Low set point 2 output
This unit is designed for use according to your measurement purposes.
Before use, follow the procedures below from installation to the start of operation.
(1) Installation of waterproof gasket
(2) Fixation to the panel
View from
the front
Panel
(1) Connection with the power
(2) Connection with various sensors
View from
the back
Connecting wires
Simple setting
●Parameter settings are not necessary.
Start of operation
Mode
(function)
settings
p.8 - 15
Memory function
settings
p.17 - 19
Parameter settings
p.8 - 15
Teaching function settings
P7
(1) Press the MEM key once to
display the MAX value.
(2) Press the MEM key again to
display the MIN value.
(3) Press the MEM key once again
to display the normal measurement
value.
*You can use the unit without
setting various functions.
(1) Press the SHIFT + MOD keys
and start setting.
(2) Use the
s
key to set, and use
the SET key to finish setting.
(1) Press and hold the SHIFT +
PAR keys for 5 seconds or
more and start setting.
(2) Press the
s
key to select the
item, and press the ENT key
to start changing the setting
value.
(3) Press the key to move to
another digit, and after
changing the value using the
● key, use the ENT key to
finish the setting value change.
(3) After setting all parameters,
use the SET key to finish setting.
(1) Press and hold the SHIFT +
FUNC keys for 5 seconds or
more and start setting.
(2) Press the
s
key to select the
item, and press the ENT key
to start changing the setting
value.
(3) Press the
key to move to
another digit, and after
changing the value using the
s
key, use the ENT key to
finish the setting value change.
(4) After setting all functions, use
the SET key to finish setting.
Function
(action configuration)
settings
p.8
p.16 -17
Input type
Symbol
Input type
501X
Standard input : Supports the sensor input, including rotary encoders, and magnetic sensors
501F(AC Power only) Differential input Supports the line driver output, including AC servo motors
Power
Symbol
Power
A
AC power (85 - 264VAC)
D
DC power (10.8 - 25.2VDC)
t
t