DFS1/DFS2 Power Installation Guide
41
Issue Number: 2
Saf
e
Pr
Mecha
El
Te
4.10
Motor cables
Capacitance in the motor cable causes loading on the output of the drive. The loading increases with
switching frequency. The maximum recommended motor cable lengths for a range of switching
frequencies are shown in Table 4-6.
Table 4-6 Maximum motor cable lengths
Model
Maximum permissible motor cable length for each of the following switching
frequencies
2 kHz
3 kHz
4 kHz
6 kHz
8 kHz
12 kHz
16 kHz
400 V
xxxx-DFS1G4EN
250 m (820 ft)
187 m
(614 ft)
125 m
(614 ft)
93 m
(305 ft)
62 m
(203 ft)
46 m
(151 ft)
xxxx-DFS1H4EN
xxxx-DFS1J4EN
xxxx-DFS1K4EN
xxxx-DFS1L4EN
xxxx-DFS1M4EN
xxxx-DFS1N4EN
250 m (820 ft)
187 m
(614 ft)
125 m
(614 ft)
93 m
(305 ft)
xxxx-DFS1P4EN
250 m (820 ft)
187 m
(614 ft)
125 m
(614 ft)
93 m
(305 ft)
xxxx-DFS1Q4EN
250 m (820 ft)
187 m
(614 ft)
125 m
(614 ft)
93 m
(305 ft)
xxxx-DFS2L4EN
250 m (820 ft)
187 m
(614 ft)
125 m
(614 ft)
93 m
(305 ft)
xxxx-DFS2M4EN
250 m (820 ft)
187 m
(614 ft)
125 m
(614 ft)
93 m
(305 ft)
xxxx-DFS2N4EN
250 m (820 ft)
187 m
(614 ft)
125 m
(614 ft)
93 m
(305 ft)
xxxx-DFS2P4EN
250 m (820 ft)
187 m
(614 ft)
125 m
(614 ft)
93 m
(305 ft)
xxxx-DFS2Q4EN
250 m (820 ft)
187 m
(614 ft)
125 m
(614 ft)
93 m
(305 ft)
Summary of Contents for DFS 1