26
support.hysecurity.com
CONFIGURE THE SETUP MENU
(SWING)
The first time you power on the SmartCNX controller you
must select an option for three settings: SET CLOCK,
USAGE CLASS, and GATE HANDING.
Figure 42.
Configuring Setup Menu
1. Press SELECT twice, press the UP or DOWN arrow
to select the right month (MM), press SELECT, and
press the DOWN arrow to move the indicator to day
(DD). Repeat the process to set the day and move to
the next part until you are done setting the date and
time.
2. Press SELECT when USAGE CLASS appears, press
the UP or DOWN arrow to select the correct USAGE
CLASS, press SELECT, and press the UP or DOWN
arrow once.
3. Press SELECT when GATE HANDING appears,
press the UP or DOWN arrow to select the correct
option, and press SELECT.
4.
The SmartCNX controller resets, flashes all LED
lights, clears the display, and returns to the gate
status display.
5. Press SELECT when SCAN FOR BLUEBUS appears,
press the UP or DOWN arrow to select YES, let the
scan complete, and press BACK until gate status
appears on the display.
HYSECURITY
B.1.00
MM/DD/YY HH:MM
SET CLOCK
1 , 2 , 3 , 4
USAGE CLASS
0 , 1 (RIGHT) , 2 (LEFT)
GATE HANDING
HYSECURITY
GATE OPEN
0 - No Handing set. Gate will not move until
handing is set.
1 - Right-hand gate opening. Looking at the
gate from the operator side, it opens to
the right.
2 - Left-hand gate opening. Looking at the
gate from the operator side, it opens to
the left.
HySecurity Gate Status.
Gate status will be OPEN/CLOSED/STOP.
INITIAL SETUP
NAVIGATE THE MENUS
Press MENU/BACK to enter the menus or to exit the
current screen (up one level without saving any changes).
Press the UP or DOWN arrow to change the current
selection until you find the one you want.
Press SELECT to access the menu or sub-menu. Press
SELECT to accept the current option or value.
Note: These navigation instructions are the same
throughout the SmartCNX controller menus.
Note: Switch limit sensor plugs if necessary.
Note: If the gate is in one position, but the display shows
the other (e.g. gate is Open, but display says
CLOSED) swap the limit sensor plugs L1 and L2 at
the drive module.