25
MX4777 Rev. D ©2021
USER INTERFACE
Figure 41. SmartCNX Controller User Interface
1.
OLED Display –
16 characters per line, 2 line display.
Displays current operator status, menus, and alerts/
faults/errors. In h6.03 and later firmware, the display
will shut off when none of the on board buttons have
been pressed for a while. Pressing any button will turn
it back on. This is to save power and extend the life of
the display.
2.
Up/Down Arrows –
Navigate through menu and
display options while in Menu Mode.
3.
Menu/Back –
Open the configuration menu from the
operator status display. Go back from the current
menu (exit the current menu).
4.
Status LED –
Indicates gate operator status
a. Flashing Red – An Alert, Fault, or Error has
occurred. Immediately shut down the machine
and correct the fault.
b. Solid Red – Operator is in Menu Mode
c. Flashing Green – Operator is in Run Mode
d. Flashing Blue – Operator is pairing with a
Bluetooth device.
e. Alternating Blue and Red/Green – Operator is
communicating with a Bluetooth device.
5.
Limit Open/Close –
Solid green when target magnet
activates limit sensor.
6.
Stop/Select –
Stops gate travel when in run mode.
Press to select current menu option or to confirm
setting value
7.
Close –
Closes the gate while in Run Mode.
8.
Open –
Opens the gate while in Run Mode.
9.
Reset –
Press to clear faults and return to Run Mode.
Cannot be used in Menu Mode.
Note: You can configure the menus on battery power
when an external power source is not yet present.
2
6
8
7
3
4
1
9
5