Nice DPRO924 Instructions And Warnings For Installation And Use Download Page 5

English – 

1

EN

GENERAL WARNINGS: SAFETY - INSTALLATION - USE (original instructions in Italian)

CAUTION

Important safety instructions. Follow all instructions as improper installation may cause serious damage

CAUTION

Important safety instructions. It is important for you to comply with these instructions for your own and other 

people’s safety. Keep these instructions

Before commencing the installation, check the “Product technical specifications”, in particular whether this product is suitable for automating 
your guided part. If it is not suitable, DO NOT continue with the installation.

• The product cannot be used before it has been commissioned as specified in the chapter on “Testing and commissioning”

CAUTION

According to the most recent European legislation, the implementation of an automation system must comply 

with the harmonised standards provided by the Machinery Directive in force, which enables declaration of 

the presumed conformity of the automation. Taking this into account, all operations regarding connection to 

the electricity mains supply, as well as product testing, commissioning and maintenance, must be performed 

exclusively by a qualified and skilled technician!

Before proceeding with the installation of the product, check that all materials are in good working order and suited to the intended applications

The product is not intended for use by persons (including children) with reduced physical, sensory or mental capacities, nor by anyone with 
insufficient experience or familiarity

Children must not play with the appliance

Do not allow children to play with the control devices of the product. Keep the remote controls out of reach of children.

CAUTION

In order to avoid any danger from inadvertent resetting of the thermal cut-off device, this appliance must not be 

powered through an external switching device, such as a timer, or connected to a supply that is regularly powered 

or switched off by the circuit

Provide a disconnection device (not supplied) in the plant’s mains power supply, with a contact opening distance that permits complete 
disconnection under the conditions dictated by overvoltage category III

Handle the product with care during installation, taking care to avoid crushing, denting or dropping it, or allowing contact with liquids of any 
kind. Keep the product away from sources of heat and naked flames. Failure to observe the above can damage the product, and increase the 
risk of danger or malfunction. If this should happen, stop installation immediately and contact Customer Service.

The manufacturer assumes no liability for damage to property, items or persons resulting from non-compliance with the assembly instructions. 
In such cases the warranty for material defects is excluded

The weighted sound pressure level of the emission A is lower than 70 dB(A)

Cleaning and maintenance to be carried out by the user must not be carried out by unsupervised children

Before working on the system (maintenance, cleaning), always disconnect the product from the mains power supply

Check the system periodically, in particular all cables, springs and supports to detect possible imbalances, signs of wear or damage. Do not use 
if repairs or adjustments are necessary, because a failure with the installation or an incorrectly balanced automated system may lead to injury

The packing materials of the product must be disposed of in compliance with local regulations

Special warnings in relation to European directives applicable to the product

“Construction Products” Regulation: Special warnings for this product in relation to Regulation 305/2011:

- The full installation of this product, as described in this instruction manual and for certain types of use (e.g. excluding use solely for vehicles) 

may cause the product to fall within the scope of Regulation No. 305/2011 and its harmonised standard EN 13241-1.

- It is necessary to apply all the installation criteria to ensure that the product meets the essential requirements of Regulation No. 305/2011; 

the installer must check and make sure that all these criteria have been scrupulously complied with.

- The essential requirements might not be guaranteed if the product is installed and used without compliance with one or more of these 

criteria. It is forbidden to use the product in such circumstances until the installer has verified compliance with the Directive requirements; 

in this case the “ES13241-1.4870” label attached to the product must be removed immediately and the “EC Declaration of Conformity” 

(Annex I to this manual) cannot be used. As a result, the installer in turn becomes the manufacturer of the product and must comply with 

the provisions of Regulation No. 305/2011 and its harmonised standard EN 13241-1. In this case the product must be considered as 

“partly-completed machinery” and the “Declaration of Conformity” of Annex II can be used (for inclusion in the technical documentation). 

“Low Voltage” Directive:

Special warnings regarding the fitness of use of this product in relation to the “Low Voltage” Directive. This product meets the requirements 

in the “Low Voltage” Directive, if used for the use and in the configurations specified in this instruction manual and in combination with the 

items in the Nice S.p.a. product catalogue.

If the product is used in unspecified configurations or with other unspecified products, the requirements may not be guaranteed; the use 

of the product in such circumstances is prohibited until the installer has verified compliance with the specified requirements of the directive.

“Electromagnetic compatibility” Directive:

Special warnings regarding the fitness of use of this product in relation to the “Electromagnetic compatibility” Directive.

This product has been subjected to electromagnetic compatibility tests in the most critical situations of use and in the configurations specified 

in this instruction manual and in combination with the items in the Nice S.p.a. product catalogue.

If the product is used in unspecified configurations or with other unspecified products, the electromagnetic compatibility may not be guar-

anteed; the use of the product is prohibited in such circumstances until the installer has verified compliance with the specified requirements 

of the directive.

Installation criteria and special warnings in connection with essential requirements

When installed correctly, this product meets the essential requirements laid down in Regulation No. 305/2011 according to the requirements 

in harmonised standard EN 13241-1, as indicated in Table 1 and in the European directive on “Machinery” 2006/42/EC.

Release of dangerous substances:

The product does not contain and/or release hazardous substances in accordance with the requirements of EN 13241-1, 4.2.9 and accord-

ing to the list of substances on the website of the European Community

Special warning to ensure the continued compliance with the requirement – It is essential that the other materials used in the installation, 

such as electrical cables, comply with this requirement.

Safe opening for vertically moving doors: the product does not cause uncontrolled movements.

Special warnings to ensure continued compliance of the requirements:

- Install the product carefully following all the instructions described in Chapter “2 - Installation” and Chapter “5 - Testing and commissioning”.

- Ensure that a maintenance schedule is organised which scrupulously complies with all the provisions in the Chapter “Maintenance 

Schedule”.

Summary of Contents for DPRO924

Page 1: ...DPRO924 Nice Control unit EN Instructions and warnings for installation and use...

Page 2: ...C A D F E B 9 6 5 8 2 3 8 4 4 7 1 2 1 210 125 310 125 310 I...

Page 3: ...3 A B 4 A B C 6 1 2 1 2 FUSE FUSE OXI New Generetion OXI SMXI II...

Page 4: ...tal deletion of the control unit s memory 6 4 3 Learning about the safety devices and DIP SWITCH programming 6 4 4 Learning about the Opening and Closing positions with an incremental encoder 6 4 5 Op...

Page 5: ...product as described in this instruction manual and for certain types of use e g excluding use solely for vehicles may cause the product to fall within the scope of Regulation No 305 2011 and its har...

Page 6: ...he ducting for routing the electrical cables and for the cable entry point into the control unit housing be aware that due to possible deposits of water in the junction wells the connection ducts migh...

Page 7: ...unit 1 24V motor 2 24V motor 3 motor Limit Switch function unavailable Connector for the electromechanical limit switch connection Common limit switch common Open input of maximum opening limit switch...

Page 8: ...stance output During the recognition phase the control unit recognises the type of device con nected and causes a STOP whenever any variation in the recognised status occurs Multiple devices even of d...

Page 9: ...ed system in a thorough and rapid manner You can connect Oview to the control unit via the IBT4N interface using a bus cable with 4 wires inside To access the BusT4 connector you need to open the cont...

Page 10: ...door Opening and Closing positions must be carried out one after the other and without interruptions They cannot be performed at different times CAUTION Procedure for motors with incremental encoders...

Page 11: ...y to set the dip switches to OFF TABLE 3 DIP SWITCH A DIP1 DIP2 DIP3 DIP4 Function OFF OFF OFF OFF Hold to run movement ON X OFF OFF Acquisition of positions and status of the ALT input OFF ON OFF OFF...

Page 12: ...10 years This must include at least an assembly drawing of the automated system a wiring diagram an analysis of hazards and solutions adopted a manufacturer s declaration of conformity of all the devi...

Page 13: ...Connecting photocells in Phototest mode The Phototest function increases the reliability of the safety devices allowing reaching category II in compliance with the EN 13849 1 standard set of the contr...

Page 14: ...e CAUTION The electrical connection of the buffer battery to the control unit must be done only after completing all the installation and programming phases since the battery is an emergency supply 6...

Page 15: ...shing light the diagnostics signals continue for two sequences of flashes e g 3 flashes short pause 3 flashes long pause repeated twice Configured with the Oview programmer as Flashing Light 1 TABLE 7...

Page 16: ...iew OUT3 output With clean contact relay programmable with Oview Aerial input 52ohm for RG58 type cable or similar for OXI New Generetion use the aerial connector on the receiver STOP input For contac...

Page 17: ...n the product conforms to the following directive in accordance with the provisions applicable to partly completed machinery Directive 2006 42 EC OF THE EUROPEAN PARLIAMENT AND COUNCIL of May 17 2006...

Page 18: ...www niceforyou com Nice SpA Via Callalta 1 31046 Oderzo TV Italy info niceforyou com IS0662A00MM_31 07 2018...