Nice DPRO924 Instructions And Warnings For Installation And Use Download Page 10

6

 – English

EN

4.1 - Control unit buttons

8

The “OPEN”, “STOP” 

and “CLOSE” buttons 

are to be used to con-

trol the automated 

system and for the 

programming phase 

OPEN

STOP

CLOSE

ON

A

B

1

2

3

1

2

3

4

ON

OFF

OFF

4.2 - Total deletion of the control unit memory

You can delete all the data stored on the control unit and restore it to its original 

state with the default settings.

01.

 

Set dip switch A 1-2-3-4 

to ON = the led flashes 

quickly with orange light

ON

1

2

3

4

A

02.

 

Keep the STOP button 

pressed for 3 seconds 

until the led is on with 

fixed red light

3”

03.

 

Release the STOP 

button

04.

 

At this point the control 

unit does a RESET = the 

led flashes quickly with 

orange light

RESET

05.

 

Set dip switch A 1-2-3-4 

to OFF = the led flashes 

with green light

OFF

1

2

3

4

A

4.3 -  Learning about the safety devices and DIP SWITCH pro-

gramming

After switching on for the first time (paragraph 3.7) and before setting the door 

Opening and Closing positions, the control unit must recognize the:

- safety devices connected to the “STOP Safety Edge” input

- photocell connection in standard or phototest mode

- settings of dip switches A and B.

NOTE

:  when  dip  switch  A  or  B  is  modified,  the  OK  led  flashes  alternatively 

green and red to highlight that the device learning phase must be carried out 

again.

 CAUTION! - During the learning phase, at least one safety device 

must be connected to the control unit. 

01.

 

Set dip switch A-1 to 

ON = the led flashes 

quickly with green light

ON

OFF

1

2

3

4

A

02.

 

Keep the STOP button 

pressed for 3 seconds 

until the led is on with 

fixed red light (after 

about 3 seconds)

3”

4

PROGRAMMING 

03.

 

Release the STOP 

button

04.

 

Set all dip switches to 

OFF = the green led 

flashes slowly or as per 

previous programming

OFF

1

2

3

4

A

1

2

3

B

This procedure must be repeated when a change to the “STOP Safety Edge” 

terminal (e.g. after connecting a device to the control unit) or the phototest 

connection or dip switches A or B is made.

After learning about the safety devices in the automation, the control unit must 

recognize the door Opening and Closing positions.

  CAUTION!

 - The procedures to learn about the safety devices and the 

door Opening and Closing positions must be carried out one after the other 

and without interruptions. They cannot be performed at different times.

 CAUTION!

 - Procedure for motors with incremental encoders: after per-

forming the Opening and Closing position learning procedure, the control unit 

must perform a self-learning procedure of the forces (5 cycles of complete 

manoeuvres, the door stops in the Closing position).

4.4 - Learning the Opening and Closing positions with an 

incremental encoder

3 positions can be programmed, as described below:

Position

Action

Meaning

0

Close

Maximum closing value. When the door 

reaches this position, it stops; this match-

es the mechanical stop (generally the floor). 

It can be programmed with the electronic 

board or Oview programmer.

1

Opening 

stop

Door maximum opening position, correspond-

ing to the opening mechanical stops (

M

 in the 

picture below). The opening value must be 

smaller than this point.

A

Open

Door stop desired position during opening 

(does not match the opening mechanical 

stops). It can be programmed with the elec-

tronic board or Oview programmer.

B

Partial 

opening

Door stop desired position during partial 

opening. It can be programmed with the 

electronic board or Oview programmer.

RA

Slow down 

Open

Door desired position for slow down start 

during opening. It can be programmed only 

with the Oview programmer.

RB

Slow down 

Close

Door desired position for slow down start 

during closing. It can be programmed only 

with the Oview programmer.

Note

: positions 

B

RA

 and 

RB

 are calculated automatically by the control 

unit; to change them, the Oview programmer must be used (accessory).

1

A

M

RA

B

RC

0

These manoeuvres are carried out at low speed. If the door is in the closing po-
sition, it must be positioned manually at about 50 cm from the ground, using the 
emergency system (see the motor instruction manual) in order to prevent, if the 
rotation is reversed, the track ropes from coming out of their housing (sectional 
doors) or the excessive winding of the shutters (rolling shutters).

 Important - Unlocking with Nice SUMO motor:

 when the SUMO mo-

tor is unlocked, if the DPRO924 control unit is on, it stores the command. To 
synchronize the encoder position again, closing as far as the maximum closing 
position must be performed. The opening manoeuvre must be carried out in 

Summary of Contents for DPRO924

Page 1: ...DPRO924 Nice Control unit EN Instructions and warnings for installation and use...

Page 2: ...C A D F E B 9 6 5 8 2 3 8 4 4 7 1 2 1 210 125 310 125 310 I...

Page 3: ...3 A B 4 A B C 6 1 2 1 2 FUSE FUSE OXI New Generetion OXI SMXI II...

Page 4: ...tal deletion of the control unit s memory 6 4 3 Learning about the safety devices and DIP SWITCH programming 6 4 4 Learning about the Opening and Closing positions with an incremental encoder 6 4 5 Op...

Page 5: ...product as described in this instruction manual and for certain types of use e g excluding use solely for vehicles may cause the product to fall within the scope of Regulation No 305 2011 and its har...

Page 6: ...he ducting for routing the electrical cables and for the cable entry point into the control unit housing be aware that due to possible deposits of water in the junction wells the connection ducts migh...

Page 7: ...unit 1 24V motor 2 24V motor 3 motor Limit Switch function unavailable Connector for the electromechanical limit switch connection Common limit switch common Open input of maximum opening limit switch...

Page 8: ...stance output During the recognition phase the control unit recognises the type of device con nected and causes a STOP whenever any variation in the recognised status occurs Multiple devices even of d...

Page 9: ...ed system in a thorough and rapid manner You can connect Oview to the control unit via the IBT4N interface using a bus cable with 4 wires inside To access the BusT4 connector you need to open the cont...

Page 10: ...door Opening and Closing positions must be carried out one after the other and without interruptions They cannot be performed at different times CAUTION Procedure for motors with incremental encoders...

Page 11: ...y to set the dip switches to OFF TABLE 3 DIP SWITCH A DIP1 DIP2 DIP3 DIP4 Function OFF OFF OFF OFF Hold to run movement ON X OFF OFF Acquisition of positions and status of the ALT input OFF ON OFF OFF...

Page 12: ...10 years This must include at least an assembly drawing of the automated system a wiring diagram an analysis of hazards and solutions adopted a manufacturer s declaration of conformity of all the devi...

Page 13: ...Connecting photocells in Phototest mode The Phototest function increases the reliability of the safety devices allowing reaching category II in compliance with the EN 13849 1 standard set of the contr...

Page 14: ...e CAUTION The electrical connection of the buffer battery to the control unit must be done only after completing all the installation and programming phases since the battery is an emergency supply 6...

Page 15: ...shing light the diagnostics signals continue for two sequences of flashes e g 3 flashes short pause 3 flashes long pause repeated twice Configured with the Oview programmer as Flashing Light 1 TABLE 7...

Page 16: ...iew OUT3 output With clean contact relay programmable with Oview Aerial input 52ohm for RG58 type cable or similar for OXI New Generetion use the aerial connector on the receiver STOP input For contac...

Page 17: ...n the product conforms to the following directive in accordance with the provisions applicable to partly completed machinery Directive 2006 42 EC OF THE EUROPEAN PARLIAMENT AND COUNCIL of May 17 2006...

Page 18: ...www niceforyou com Nice SpA Via Callalta 1 31046 Oderzo TV Italy info niceforyou com IS0662A00MM_31 07 2018...

Reviews: