35
Steps on how to place the Apollo 1050 control board into learning mode.
1. Press Function
2. Press OK
3. Select Swing
4. Select weight of gate (LIGHT , AVERAGE, or HEAVY)
5. Press Enter
Unit should now be in
LEARNING MODE
16 - APOLLO T5/T7 PROGRAMMING QUICK START
17 - Putting the controller into learning mode
Learning T5ETL-1K/T7ETL-1K Actuator
1. Install electrical power to the gate opener unit.
2. Install all gate accessories such as Photo-Eye’s, Sensors, Loops and other safety devices.
3. Turn on the electrical power to the unit.
4. Using the MANUAL RELEASE HANDLE, disengage the drive motor. See Figure 16
- T5/T7X
MANUAL RELEASE.
5. Move the gate manually (with your hands) to ensure that the gate travels to the fully open and
fully closed positions with no binding or problems. Gate should move freely.
6. Using the MANUAL RELEASE HANDLE, re-engage the drive system and stow the handle.
See Figure 17 - T5/T7 MANUAL ENGAGE.
7. Using the open button on the front of the Control board, hold the button down until the gate
reaches the fully open position. If the gate moves in the opposite direction swap the RED and
BLACK motor leads at the 3-pin motor power connector on the control board.
8. Adjust the Open Limit Switch until the GREEN light illuminates on the front of the control
board. The FULLY OPEN limit switch is now set.
9. Using the CLOSE button on the front of the Control Board, hold the button down until the gate
reaches the fully closed position.
10. Adjust the CLOSED Limit Switch until the RED light illuminates on the front of the control
board. The fully CLOSED limit switch is now set.
11. The control board is already in the “LEARNING MODE” when shipped. If not in LEARNING
MODE, press FUNCTION, then press LEARN, then press SWING, then select LIGHT, AVER-
AGE < or HEAVY, then press ENTER to start the gate learning process.
12. The gate will open partially then stop. This is being done, so that the control board can sense
the type and operational condition of the drive motor. The gate will then run to the closing lim-
it, so that it can properly sense where it is located.
13. The control board will then OPEN the gate slowly to establish travel and limits.
14. Once the gate reaches the fully OPENED limit switch, the control board will now increase
gate travel speed to the highest speed allotted, and will now travel to the fully CLOSED posi-
tion at full speed.
15. The gate opener is now programmed for basic usage.