10
1.4 - Attaching the oper-
ator to the pivot bracket
and attachment
(Continued)
Connect the front of the T5/T7
to the attachment bracket us-
ing the supplied bolt and
washer with a 13mm metric
socket as shown in Figure 8
CONNECTING TO AT-
TACHEMENT BRACKET.
Be careful not to over tighten
the bolt.
1 - T5ETL-1K AND T7ETL-1K OPERATOR INSTALLATION (Continued)
1.5 - Connect power cable
and attach individual wires
Unlock the strain relief bushing locat-
ed on the bottom of the T5/T7 near
the pivot bracket mounting bolt by
rotating the nut counter-clockwise
and insert the 7-conductor power ca-
ble through the bushing to the top of
the T5/T7 as shown in Figure 9 IN-
SERTING AND SECURING POWER
CABLE. Ensure there is sufficient
conductor on the topside of the T5/
T7 to make connections, and then
tighten the nut clockwise to secure
the cable in the strain relief bushing.
Figure 9 - INSERTING AND SECURING POWER CABLE
Figure 8 - CONNECTING TO THE ATTACHMENT BRACKET
NOTE: USE 13mm METRIC SOCKET
Loosen Brushing nut to insert cable
Tighten bushing