28
11.5 - Function
Learn:
Puts the gate operator into learning mode for a Swing or Slide gate and Blue BUS
peripherals. Learning mode for a
Swing or Slide
style gate involves selecting the gate type
(Light, Average, Heavy), then fully opening and closing the gate to sense the limits. Selecting
the gate type selects precalculated values for the FORCE, SPEED, and ACCELERATION
settings. Learning the Blue BUS peripherals enables the gate operator to discover and inte-
grate accessory devices like Blue BUS access control and safety devices.
Positions:
Configures the points in the gate open, close, and partial cycles at which decel-
eration occurs.
Slow Down –
Open: Sets the point in the % of gate opening when the gate begins decel-
eration to the fully open position.
Slow Down –
Close: Sets the % of gate opening when the gate begins deceleration to
the fully close position.
Partial:
Sets the point in the % of gate opening when the gate begins deceleration to the
Partial open position.
Auxiliary Inputs:
Auxiliary inputs IN AUX1 (16) and IN AUX2 (18) can be programmed
with one of the following options:
• No program No Function used
• OPEN the Gate
• CLOSE the Gate
• STEP Cycling Step (Open-Stop-Close-Stop)
• PARTIAL opening
• PARTIAL 1 Partial Opening 1 (open one leaf in dual gate applications)
• STOP the gate and Auto-closing
• HOLD TO OPEN Input must be maintain active for Opening
• HOLD TO CLOSE Input must be maintain active for Closing
• FIRE Reset Hard Shut Down and Open the Gate
• TIMER 1 Start Count Down TIMER1
• TIMER 2 Start Count Down TIMER2
• PHOTO Photocell PHOTO input: reverse to opening when closing
• PHOTO1 Photocell PHOTO1 input: Stop Gate when activated
• PHOTO2 Photocell PHOTO2 input: reverse to closing when opening
• SHADOW Loop input: prevent closing gate when completely open
• LOCK system from other command (only STEP H overrides the Block)
• UNLOCK Un-lock the system if locked
• OPEN and LOCK Open the Gate and inhibit further commands (except STEP H)
• CLOSE and LOCK Close the Gate and inhibit further commands (except STEP H)
• OPEN and UNLOCK Open the Gate and un-inhibit further commands
• CLOSE and UNLOCK Close the Gate and un-inhibit further commands
• STEP H Command high priority Step cycling (open-stop-close-stop
Auxiliary Outputs:
Auxiliary outputs OUT AUX1 (1,2,3,) and OUT AUX2
(4,5,6,) can be programmed with one of the following options:
NO PROGRAM Output not used
OPEN Output is activated when Gate is open
CLOSE Output is activated when Gate is closed
MOVING Output is activated when Gate is moving
TIMER 1 Output is activated when TIMER1 is counting down
TIMER 2 Output is activated when TIMER2 is counting down
LOCK Output is activated when the Gate is locked
MAINT Output is activated when the maintenance cycle counter decrements to 0