49
NIBE BA-SVM 10-200
Menu 1.9.5 - Cooling operation settings
Menu 1.9.7 - My curve
Menu 1.9.8 - Point offset
heat./cool. sensor
An extra temperature sensor can be connected to the
heat pump in order to determine when it is time to
switch between heating and cooling operations.
When several heating/cooling sensors are installed,
you can select which one of them should be in control.
start active cooling
Here you can set when active cooling is to start. Degree
minutes are a measurement of the current heating de-
mand in the house and determine when the compres-
sor, cooling operation or additional heat will be started/
stopped.
In this menu, you can create your own heating or
cooling curve by setting the desired supply tempera-
tures for different outdoor temperatures.
BA-SVM 10-200 can be used to cool the house during
hot periods of the year. For more information select "
?".
Changes to the heating curve at a certain outdoor
temperature are selected here. One step is usual-
ly enough to change the room temperature by one
degree, but in some cases several steps may be re-
quired.
The heating curve is affected at ± 5 °C from the set
outdoor temperature point.
It is important that the correct heating curve is select-
ed so that the room temperature is experienced as
constant. For more information select "?".
NOTE
When the heating/cooling sensors BT74 have been
connected and activated in menu 5.4, no other sensor
can be selected in menu 1.9.5.
NOTE
Curve 0 in menu 1.9.1 must be selected in order for
“My curve” to apply.
NOTE
“My curve” may only be edited by qualified persons.
NOTE
Point offset may only be edited by qualified persons.
Menu 2 - HOT WATER
The hot water menu is used for adjusting hot water
settings. The user can edit temperatures and oper-
ating modes for hot water. Within this menu there
are several submenus. Status information for the rel-
evant menu can be found on the display to the right
of the menus.
Activation of a temporary increase in the hot water
temperature. Status information reads “off”, or the du-
ration of the temporary increase in temperature. For
more information select "?".
Factory settings: off
When hot water demand has temporarily increased,
this menu can be used to select an increase in the hot
water temperature to luxury mode for a specified time.
Factory settings:
Delta at +20 C.: 3 °C
Delta at +40 C.: 6 °C
Heat./cool. sensor: N/A
Alarm - room sens. cooling: deactivated
Start active cooling 30 DM
Time betw. switch heat/cool: 2 hours
Section 9 |
Control
Menu 2.1 - Temporary lux.