NIBE BA-SVM 10-200
Menu 1.9.2 - External adjustment
Menu 1.9.3 - Min. supply temp.
Menu 1.9.4 - Room sensor settings
Connecting an external contact, for example, a room
sensor or a timer allows you to temporarily or peri-
odically raise or lower the room temperature while
heating. When the external contact is activated, the
offset heating curve is changed by the number of
steps selected in the menu. If a room sensor is in-
stalled and activated, the desired room temperature
(°C) will be set.
If there is more than one climate system, separate set-
tings can be entered for each system. For more infor-
mation select "?".
Room sensors to adjust the room temperature (not in-
cluded) can be activated here.
Here you can set a factor (a numerical value) that deter-
mines how much an over or sub normal temperature
(the difference between the desired and actual room
temperature) in the room is to affect the supply tem-
perature to the climate system. A higher value gives a
greater and faster change of the offset heating curve.
For more information select "?".
Select heating or cooling operation in menu 1.9.3, and
in the next menu (min. supply temp.heating/cooling)
set the minimum supply temperature of the climate
system. This means that BA-SVM 10-200 never calcu-
lates a temperature lower than the one set here.
If there is more than one climate system, separate
TIP
Wait 24 hours before changing settings again, so that
the room temperature has time to stabilise.
If it is cold outdoors and the room temperature is too
low, increase the curve slope by one step.
If it is cold outdoors and the room temperature is too
high, reduce the curve slope by one step.
If it is warm outdoors and the room temperature is too
low, increase the curve offset by one step.
If it is warm outdoors and the room temperature is too
high, reduce the curve offset by one step.
TIP
The value can be increased if you have, for example, a
cellar that should always be heated, even in summer.
You can also increase the values in “stop heating”,
menu 4.9.2 “Auto mode setting”.
Factory settings:
Heating
Climate system 1: 0
Cooling (if activated)
Climate system 1: 0
Factory settings:
Heating
Climate system 1: 20 °C
Cooling (if activated)
Climate system 1: 18 °C
Factory settings:
off
CAUTION
Too high a set value for “system factor” can (depend-
ing on your climate system) produce an unstable room
temperature.
NOTE
A slow heat-releasing heating system such as, for ex-
ample, underfloor heating, may not be suitable for con-
trol using the heat pump’s room sensor.
settings can be entered for each system.
Section 9 |
Control