CONNECTION, REVERSING VALVE MOTOR
(CL11-QN19)
Connect the reversing valve (QN19) to AA5-X9:5, X9:6
and AA5-X10:2 in the AXC module (AA25).
1
2
3
4
5
6
7
8
9
AA5-X9
AA5-X10
1
2
1
M
AA25
External
Black
Blue
Brown
QN19
DIP SWITCH
The DIP switch on the accessory card must be set as
follows.
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
Pool 1
Pool 2
PROGRAM SETTINGS
Program setting of AXC 30 can be performed via the
start guide or directly in the menu system.
START GUIDE
The start guide appears at first start-up after the heat
pump installation, but it can also be found in menu 7.7.
MENU SYSTEM
If you do not make all settings via the start guide or need
to change any of the settings, this can be done in the
menu system.
Menu 7.2.1 - Add/remove accessories
Here, you state which accessories are installed for the
compatible product.
To identify connected accessories automatically, select
"Search for accessories". It is also possible to select ac-
cessories manually from the list.
Menu 7.2.17 - Pool (POOL)
Activate/Deactivate Pool
Start temperature
Setting range: 5.0 – 80.0 °C
Stop temperature
Setting range: 5.0 – 80.0 °C
Max. number of compressors
Setting range: 1-18
Desired charge power
Setting range: 1-100 kW
Activate/Deactivate:
Here, you activate or deactivate
pool heating.
Start and Stop temperature
: Here, you set the start and
stop temperature of pool heating.
Max. number of compressors
: Here, you select the
number of compressors that will heat the pool.
Desired charge power
: Here, you select the desired
charge power to the pool.
TIP
The same settings can be made for Pool 2.
Caution
The start temperature cannot be set to a value
that is higher than the stop temperature.
Menu 7.1.2.4 - Pump speed charge pump
Make settings here for the charge pump’s speed in the
current operating mode, for example in heating or hot
water operation. Which operating modes can be
changed depends on which accessories are connected.
35
AXC 30 S-series | GB