PROGRAM SETTINGS
Program setting of multi-installation during operation of
several heat pumps can be performed via the start guide
or directly in the menu system.
The start guide appears upon first start-up after heat
pump installation, but is also found in menu 7.7.
If you do not make all settings via the start guide or need
to change any of the settings, this can be done in the
menu system.
MENU 7.2.1 - ADD/REMOVE ACCESSORIES
Here, you state which accessories are installed for the
compatible product.
To identify connected accessories automatically, select
"Search for accessories". It is also possible to select ac-
cessories manually from the list.
MENU 7.1.2 - CIRCULATION PUMPS
This menu contains sub-menus where you can make
advanced circulation pump settings.
MENU 7.1.2.3 - OPERAT. MODE CHARGE
PUMP
Operating mode Charge pump
Alternatives: Auto, Intermittent
Operating mode Charge pump during cooling
Alternatives: Auto, Intermittent
Auto
: The charge pump runs according to the current
operating mode for AXC 30.
Intermittent
: The charge pump starts 20 seconds before
the compressor starts and it is turned off 20 seconds
after the compressor stops.
MENU 7.1.2.4 - PUMP SPEED CHARGE PUMP
Make settings here for the charge pump’s speed in the
current operating mode, for example in heating or hot
water operation. Which operating modes can be
changed depends on which accessories are connected.
Speed control - Heating
Alternatives: Auto/manual
Manual
Alternatives: On/Off
Speed in standby mode
Setting range: 1 – 100%
Speed control - Pool
Manual
Alternatives: On/Off
Manual speed Pool
Setting range: 1 – 100%
Speed control - Hot water
Manual
Alternatives: On/Off
Manual speed Hot water
Setting range: 1 – 100%
Speed control charge pump - Cooling
Manual
Alternatives: On/Off
Active cooling.
Setting range: 1 – 100%
Lowest permitted speed
Setting range: 1 – 50%
Highest permitted speed
Setting range: 80 – 100%
Speed control
: Here, you set whether the charge pump
will be regulated automatically or manually. Select "Auto"
for optimal operation.
Speed in standby mode
: Here, you set the speed the
charge pump will have in standby mode. Standby mode
occurs when heating or cooling operation is permitted
at the same time as there is no need for either com-
pressor operation or electric additional heat.
Speed control charge pump
: Here, you set whether the
charge pump is to be regulated automatically or via
manually controlled speed. Select "Auto" for optimal
operation.
Manual speed, charge pump:
If you have opted to con-
trol the charge pump manually, you set the desired
pump speed here. (Settings are available per demand
heating/pool/hot water/cooling.)
Lowest permitted speed
: Here, you can restrict the
pump speed, so the charge pump is not allowed to op-
erate at a lower speed than the set value.
Maximum permitted speed
: Here, you can restrict the
pump speed, so the charge pump is not allowed to op-
erate at a higher speed than the set value.
41