Transport and storage
AMB 30 must be transported and stored vertically.
Assembly
႑
Place AMB 30 outdoors on a solid level base that can
take the weight, preferably a concrete foundation.
If concrete slabs are used they must rest on asphalt
or shingle.
႑
The concrete foundation or slabs must be positioned
so that the lower edge of the evaporator is at the
level of the average local snow depth, although a
minimum of 300 mm.
႑
AMB 30 should not be positioned next to noise
sensitive walls, for example, next to a bedroom.
႑
Also ensure that the placement does not inconveni-
ence the neighbours.
႑
AMB 30 must not be placed so that recirculation of
the outdoor air can occur. This causes lower output
and impaired efficiency.
႑
Place AMB 30 protected from direct wind.
႑
Large amounts of condensation water as well as melt
water from defrosting can be produced. Condensa-
tion water must be led off to a drain or similar (see
page 6).
႑
Care must be exercised so that AMB 30 is not
scratched during installation.
LEK
LEK
PLQ PP
Do not place AMB 30 directly on the lawn or other non
solid surface.
If there is a risk of roof slides a protective roof or similar
should be installed over AMB 30, pipes and wiring.
5
Chapter 2 |
Delivery and handling
AMB 30
2 Delivery and handling
Summary of Contents for AMB 30
Page 1: ...Installer manual LEK AMB 30 Accessories F1345 IHB GB 1341 1 231417 ...
Page 2: ......
Page 47: ...Electrical circuit diagram 45 Chapter 12 Technical data AMB 30 ...
Page 48: ...AMB 30 Chapter 12 Technical data 46 ...
Page 49: ...47 Chapter 12 Technical data AMB 30 ...
Page 51: ......
Page 52: ...NIBE AB Sweden Hannabadsvägen 5 Box 14 SE 285 21 Markaryd info nibe se www nibe eu 231417 ...