Alarm list
Acknowledging alarms
No harm in acknowledging an alarm. If the cause of the
alarm remains, the alarm recurs.
■
When an alarm has been triggered, it is acknowledged
in menu 9.7 (service menu) by switching ACVM 270 off
and on using the switch (SF1). Note that when the power
is switched on there is a 30 minute delay before the heat
pump restarts.
■
When the alarm cannot be reset using the switch (SF1),
the operating mode, "Add. heat only", can be activated
to return to a normal temperature level in the house.
This is most easily carried out by holding the ”Operating
mode” button pressed in for 7 seconds.
NOTE
Recurring alarms mean that there is a fault in the in-
stallation.
Alarm with automatic reset
Resets alarm
Triggers alarm
Alarm text on the dis-
play
Alarm
no.
- When condenser supply is greater than 14 °C
during cooling.
When condenser supply (BT12) is less than 5 °C.
Low condenser out
70
- When defrosting has ended. If the defrosting
caused the alarm (condenser supply during de-
frosting is approx. 10 °C).
- When condenser out is lower than 51 °C.
When condenser supply is greater than 60 C
and more than 120 seconds have passed since
shifting to the climate system.
High KF
71
- When the low pressure is greater than 0.83
MPa (8.3 bar) and condenser out is greater than
14 degrees.
When the low pressure is less than 0.65 MPa
(6.5 bar) in cooling mode.
Anti freeze HX
72
- When the outdoor temperature rises above 1
°C.
When the outdoor temperature drops below 0
°C and the operating mode does not permit
heating.
Freeze prot
73
- When the current output decreases.
Too high current output from the house.
Current limit
75
- When the fault has been corrected.
Failed communication to one or more boards.
Com. alarm
76
- When defrost has ended.
When the temperature in the water heater is
too low (low pressure is less than 0.5 MPa, 5.0
bar) during defrost.
Defrosting interrupted
77
- When defrost has ended.
Exceeded limit value
Protection
78
Temperature limiter alarm
The following alarm blocks both AMS 10 and addition.
May be due to
Description
Alarm text on the dis-
play
Alarm
no.
- The temperature limiter has tripped during
transportation
Temperature limiter in ACVM 270 has tripped.
TB alarm
3
- High temperature in ACVM 270
- Tripped circuit fuse (L2
ACVM 270 alarm
The following alarms block AMS 10. Addition runs at min permitted supply temperature.
May be due to
Description
Alarm text on the dis-
play
Alarm
no.
- Tripped circuit fuse (L2) and (L3)
No voltage to the outdoor unit from ACVM 270.
OU power failure
4
- Tripped miniature circuit breaker (-FA2)
- Low temperature during cooling
Too low temperature out from the condenser.
Low condenser out
5
- Low flow during cooling
Occurs if alarm 70 occurs 3 times within an hour.
61
NIBE™ SPLIT ACVM 270
Miscellaneous
Alarm list
Summary of Contents for ACVM 270
Page 2: ...LEK LEK 1 2 LEK LEK 7 LEK 5 6 LEK 3 4 LEK LEK LEK LEK AMS 10 8 LEK LEK AMS 10 12 ...
Page 67: ...67 NIBE SPLIT ACVM 270 Miscellaneous Electrical circuit diagram ...
Page 68: ...NIBE SPLIT ACVM 270 68 Miscellaneous Electrical circuit diagram ...
Page 69: ...69 NIBE SPLIT ACVM 270 Miscellaneous Electrical circuit diagram ...
Page 70: ...NIBE SPLIT ACVM 270 70 Miscellaneous Electrical circuit diagram ...
Page 94: ......
Page 95: ......