Product Information
8
TemBreak
PRO
P_BE-UM-001-EN V1.3.0
Part Number Break Down
P
160 F 2 4 160 BE G
a)
b)
c)
d)
e)
f)
g)
h)
a) Model Type
A
Basic applications
(160…250 A)
P
Mid to advanced applications
(160…630 A)
B
High current, high kA applications
(160…1600 A)
ZS Earth Leakage applications
(125…800 A)
XS Highest current applications
(2000…3200 A)
b) Ampere Frame
125 A
160 A
250 A
400 A
630 A
800 A
1000 A
1250 A
1600 A
2000 A
2500 A
3200 A
c) Short Circuit Break Capacity I
cu
(kA)
R
200 kA
L
150 kA
P
125 kA
S
110 kA
G
100 kA
HL
85 kA
H
70 kA
M
65 kA
N
50 kA
F
36 kA
E
25 kA
D
Switch
d) Pole Pitch Size (mm)
1)
1 25
2 30
3 35
e) No. of Poles
1
6)
2
7)
3
4
f) Trip Unit Rating (I
n
)
I
n
x A
g) Trip Unit Type
TF
Adj Thermal Fix Magnetic
3)
FF
Fix Thermal Fix Magnetic
3)
FM Fix Thermal Adj Magnetic
8)
TM Adj Thermal Adj Magnetic
SX Smart Ammeter
4) 5)
BE Basic Electronic
5)
SE Smart Energy
5)
NN Non-Auto Switch
h) Trip Unit Option
G
Ground Fault
2)
N
Neutral
2)
P
Pre-Trip Alarm
2)
SN Solid Neutral
8)
1.
160AF only
2.
For P_SE versions these features are standard and therefore are not added to the end of the part number.
3.
Only available in A & ZS models
4.
Only available in B models
5.
Not available in A models
6.
Only available in A and B models (FF Only Trip Unit)
7.
Not available in A and B models (FF Only Trip Unit)
8.
ZS Models
Notice
: Not all combinations are possible. Confirm part number combination with NHP for availability.
Summary of Contents for TemBreak PRO P
Page 50: ...50 TemBreak PRO P_BE UM 001 EN V1 3 0 Annex A Dimensions P160 Dimensions...
Page 51: ...Annex A Dimensions 51 TemBreak PRO P_BE UM 001 EN V1 3 0 P250 Dimensions...
Page 52: ...Annex A Dimensions 52 TemBreak PRO P_BE UM 001 EN V1 3 0 P400 Dimensions...
Page 53: ...Annex A Dimensions 53 TemBreak PRO P_BE UM 001 EN V1 3 0 P630 Dimensions...
Page 55: ...55 TemBreak PRO P_BE UM 001 EN V1 3 0 Annex C I2t Let Through Curves P160_BE...
Page 56: ...Annex C I2t Let Through Curves 56 TemBreak PRO P_BE UM 001 EN V1 3 0 P250_BE...
Page 57: ...Annex C I2t Let Through Curves 57 TemBreak PRO P_BE UM 001 EN V1 3 0 P400_BE...
Page 58: ...Annex C I2t Let Through Curves 58 TemBreak PRO P_BE UM 001 EN V1 3 0 P630_BE...
Page 59: ...59 TemBreak PRO P_BE UM 001 EN V1 3 0 Annex D Peak Let Through Curves P160_BE...
Page 60: ...Annex D Peak Let Through Curves 60 TemBreak PRO P_BE UM 001 EN V1 3 0 P250_BE...
Page 61: ...Annex D Peak Let Through Curves 61 TemBreak PRO P_BE UM 001 EN V1 3 0 P400_BE...
Page 62: ...Annex D Peak Let Through Curves 62 TemBreak PRO P_BE UM 001 EN V1 3 0 P630_BE...
Page 65: ...65 TemBreak PRO P_BE UM 001 EN V1 3 0 This page is intentionally left blank...