17
Note a:
The Server allows only one NMEA instrument connected
to the input pins 9 and 10.
Note b:
We do not recommend the use of NMEA transducers like
wind and compass, because the update rate of data is slow
compared to the very fast Nexus data bus.
Note c:
If the NMEA instrument has only one output cable, put a
”bridge” cable on the Server between pins 10 (RETURN) and 12
(RETURN).(See chapter 12.6 , C75)
2.9 Connecting a NMEA instrument OUT from Server
Products receiving NMEA, for example:
Plotter, radar, Maxi repeaters, POWER Navigate.
Again you must know which 2 cables from your other NMEA
instrument carry the NMEA in signal. If you have trouble call the
dealer you bought the NMEA instrument from. He should know the
wiring colour and will probably sell the ”plug set” which may be
required. We do not have this information.
Connect NMEA in signal from NMEA instrument to Server pin 11
(OUT). Connect NMEA return signal from NMEA instrument to
Server pin 12 (RETURN). (For list of NMEA transmit sentences,
see 12.61.)
2.10 Connecting the power supply
1.
Connect the red wire from the Server pin 1 (+12V) to +12V.
Connect the black wire from the Server pin 2 (0V) to 0V.
Protect the circuit with a 3 Amp fuse/circuit breaker on the 12V
side.
INSTALLATION
3 A fuse
Black
Red
Summary of Contents for Multi Control
Page 1: ...0 Instrument and Server Installation and Operation Manual...
Page 7: ...6 PART SPECIFICATION...