background image

Electronic control unit for the automation of one 230Vac motor with built-in limit switch and 1, 2 or 3 led line in costant 

voltage tension (number of led output settable).

Motor and control unit power supply: 230Vac

Led power supply: 12 or 24Vdc

Motor output: 230 Vac max 1000 W

Led output: 5A for output (3out), max 10A in total

433.92 MHz receiver for radio transmitters.

WiFi connection for OneSmart App.

Top-ML/One: 

control unit in IP20 casing

Screen-ML/One: 

control unit in outdoor plastic box IP56

TOP

-ML/One

SCREEN

-ML/One

Top-ML400/One

Screen-ML400/One

Summary of Contents for SCREEN-ML/One

Page 1: ...r and control unit power supply 230Vac Led power supply 12 or 24Vdc Motor output 230 Vac max 1000 W Led output 5A for output 3out max 10A in total 433 92 MHz receiver for radio transmitters WiFi conne...

Page 2: ...ROL UNIT Page 9 5 MANAGEMENT WITH REMOTE CONTROL 5 1 RADIO PROGRAMMING 5 2 DELETION OF REMOTE CONTROL Page 10 Page 11 6 ADVANCED PROGRAMS 6 1 CONFIGURATION OF MANOEUVRE TIMES 6 2 CONFIGURATION OF THE...

Page 3: ...0 seconds RAIN ALARM the sensor detects water then the control unit close the motor settable function and disables the reception of remote or wired commands until the alarm is over ALARM NOT PRESENT E...

Page 4: ...paragraph 6 4 See paragraph 3 for connecting the LEDs and setting the number of outputs TERMINAL NUMBER DESCRIPTION 1 230V phase power supply 2 230V neutral power supply 3 230V phase for accessories p...

Page 5: ...common 23 Input 1 default vento 3 LED OUTPUT ELECTRICAL CONNECTIONS This control unit can manage 1 2 or 3 lines of single colour LED strip lights By default operation is set to one li strip lights If...

Page 6: ...antenna signal 18 Not used 19 Not used 20 Led power supply 12 or 24Vdc 21 Led power supply 22 Input common 23 Input 1 default vento 3 2 CONNECTING TWO LINES OF SINGLE COLOUR STRIP LIGHTS With the def...

Page 7: ...nal 18 Not used 19 Not used 20 Led power supply 12 or 24Vdc 21 Led power supply 22 Input common 23 Input 1 default vento 3 3 CONNECTING THREE LINES OF SINGLE COLOUR STRIP LIGHTS With the default setti...

Page 8: ...hts in synchronised mode 2 2 2 lines of single colour LED 3 3 3 lines of single colour LED STEP 3 Press the button P1 during the during the Flash that corresponds to the function desired to end the co...

Page 9: ...rrect or alternatively modify them see paragraph 6 2 6 3 and 6 4 If you want to control the system via radio control associate the radio transmitter with the desired output s see paragraph 5 If you wa...

Page 10: ...he transmitter to be saved See transmitter manual the paragraph entitled transmitter programming for specify information The led makes 3 Flashes and turns off ACTION Make a transmission with the trans...

Page 11: ...Within 10 seconds make a transmission with the transmitter that you want to delete The LED flashes quickly and turns off PASSO 2B Within 10 seconds press the button 1 on the receiver for a short time...

Page 12: ...Flash ACTION Short pressure button 1 LED Turns off ACTION long press button 2 LED turns on red STEP 1 Make a long press of button 2 The led turns on red STEP 3 To end the count press the button 2 for...

Page 13: ...Flashing to set the wind speed above which to intervene DEACTIVATE Press button 3 N FLASH DESCRIPTION 1 Intervention 5km h 2 Intervention 10km h 3 Intervention 15km h 4 Intervention 20km h 5 Interven...

Page 14: ...the control unit exits the procedure after 60 seconds or when a key is pressed STEP 3B To carry out the test wet the sensitive part of the rain sensor the control unit will make a brief opening moveme...

Page 15: ...e LED starts Flashing STEP 4A To end the count press the button 1 for a short time during the Flash that corresponds to the function desired FLASH FUNCTION 1 Wind sensor 2 Rain sensor 3 Sun sensor 4 M...

Page 16: ...onds make a short press of button 2 The LED 1 Flashes quickly and turns off ACTION Short press of button 2 LED The led Flash quicly and turns off ACTION Long press of button 1 LED The led Flash quicly...

Page 17: ...and for the movement of the motor but this is inhibited due to an alarm a BEEP will be emitted from the buzzer and the LED on the board will give the following signal Flashes blue for 5 sec wind alarm...

Page 18: ...control the system remotely 8 1 APP CONNECTION This procedure connects the control unit to the application It shall be repeated for each control unit on the installation ATTENTION an internet based 2...

Page 19: ...the model of router you have try to check and set these parameters WIFI FREQUENCY BAND some routers generate a network that is set automatically at a frequency of 2 4GHz or 5GHz depending on the devi...

Page 20: ...20...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Page 24: ...V1 0 Nexta Tech company brand of Team srl via G Oberdan 90 33074 Fontanafredda PN Italy Ph 39 0434 998682 Email info nexta tech com Web www nexta tech com...

Reviews: