TERMINAL
NUMBER
DESCRIPTION
1
230V phase power supply
2
230V neutral power supply
3
230V phase (for accessories power supply)
4
230V neutral (for accessories power supply)
5
Motor ouput, close (L)
6
Motor output, common (N)
7
Motor ouput, open (L)
8
230V phase (for accessories power supply)
9
230V neutral (for accessories power supply)
10
+ output led
11
+ output led
12*
OUT led 1 (-)
13*
OUT led 2 (-)
14*
Not used in this configuration
15
Not used
16*
Input 2: default= rain sensor
17
433,92MHz antenna signal
18
Not used
19
Not used
20
Led power (12 or 24Vdc)
21
Led power supply -
22
Input common
23*
Input 1: default= vento
3.2 CONNECTING TWO LINES OF SINGLE-COLOUR STRIP LIGHTS
With the default settings the control unit is set to control the three LED lines with synchronized operation.
Change the setting, follow the procedure in paragraph 3.4.
WARNING:
•
Connect up to 5A per output and max total 10A
•
The outputs are separate
•
The operation of the inputs can be set, see paragraph 6.4
L
L N
(out)
(in)
(out)
N
L
POWER SUPPLY
12 O 24VDC
N
17 18 19 20 21 22
10 11 12 13 14 15 16
23
1
2
3
4
5
6
7
8
9
-
+
(10)
+
(11)(12)
-
-
(13)(14)
(20)
(21)
(9)
(8)
2 LED LINE SINGLE COLOR
Separate control
6