6 - ADVANCED PROGRAMS
6.1 - CONFIGURATION OF MANEUVER TIMES
Default: 60 seconds
This procedure is used to set the opening and closing manoeuvre time (maximum time that can be set 180 seconds).
NOTE:
Before carrying out this procedure check that the direction of operation is correct in relation to the transmitter
keys or wired command.
ACTION:
Short pressure button 1
LED:
Flash
ACTION:
Short pressure button 1
LED:
Turns off
ACTION:
long press button 2
LED:
turns on red
STEP 1
Make a long press of button 2.
The led turns on red.
STEP 3
To end the count press the button 2 for a short time during the Flash that
corresponds to the function desired
STEP 2
Press the button 2 on the receiver for a short time and count the number of Flashes
emitted by the LED (max 180 Flashes): each Flash represents a second of manoeuvre
time.
Attention: the control unit Flashes one time every 1 second, example: 120 seconds =
120 Flashes = 2 minutes of manoeuvre
12