2 - ELECTRICAL CONNECTIONS
WARNINGS
•
Installation must be carried out only by qualified technicians in compliance with the electrical and safety standards in
force.
•
All connections must be made with the power turned off.
•
Use suitable cables.
•
Do not cut through the aerial
•
A suitably sized disconnection device must be set up on the electric power line that supplies
the product
•
Disposal of waste materials must fully respect local standards.
•
Do not exceed the load limits shown and use protected power supply units of the correct size for the load.
* NOTE:
•
Connect maximum 500W per output.
•
the inputs can be set as wired commands, see paragraph 5.4
NUMERO
MORSETTO
DESCRIZIONE
1
433,92MHz antenna signal
2*
Input1, default setting = wind sensor, function
opens at the detected speed of 10km / h
3*
Input2, default setting = rain sensor, function closes
on intervention
4*
Input3, default setting = sun sensor, function closes
on intervention
5
Not used
6
Inputs common
7
230V neutral power supply
8
230V phase power supply
9
Motor 2 close
10
Motor 2 common
11
Motor 2 open
12
Motor 1 close
13
Motor 1 common
14
Motor 1 open
15
Motor 4 close
16
Motor 4 common
17
Motor 4 open
18
Motor 3 close
19
Motor 3 common
20
Motor 3 open
9 10 11 12 13 14
15 16
15 16 17
17 18 19 20
4
5
6
1
2
3
18 19 20
7 8
ANT
N (in)
L (in)
I1, wind sensor*
I2, rain sensor*
I3, sun sensor*
C
M1
M2
M4
M3
4