![Newworld NWCMBOB User Manual Download Page 30](http://html1.mh-extra.com/html/newworld/nwcmbob/nwcmbob_user-manual_1681010030.webp)
30
Electrical connection
This appliance must be installed by a qualified electrician to comply with the
relevant Institution of Engineering and Technology (I.E.T.) regulations and
also the local electricity supply company requirements.
This appliance must not be connected to an ordinary domestic power point.
The mains terminal is situated on the back of the oven.
•
•
•
GREEN AND YELLOW = EARTH
BLUE = NEUTRAL
BROWN = LIVE.
The fuse must be rated
not less than
16
Amps.
As the colours of the wires in the mains lead for the appliance may not correspond
with the coloured markings identifying the terminals in your spur box, proceed as
follows:
7KHZLUHZKLFKLVFRORXUHGJUHHQDQG\HOORZPXVWEHFRQQHFWHGWRWKHWHUPLQDOPDUNHG(
(DUWKRUFRORXUHG*UHHQ
7KHZLUHZKLFKLVFRORXUHGEOXHPXVWEHFRQQHFWHGWRWKHWHUPLQDOPDUNHG11HXWUDORU
FRORXUHG%ODFN
7KHZLUHZKLFKLVFRORXUHGEURZQPXVWEHFRQQHFWHGWRWKHWHUPLQDOPDUNHG//LYHRU
FRORXUHG5HG
Connect the cable to the correct terminals. Check that the links are correctly
fitted and that the terminal screws are tight. Secure the mains cable using the
cable clamp. Ensure the cable route avoids the risk of trapping or touching
hot surfaces.
Warning: Connect the power cord must be in aceordance with the
instructions listed in the table below.
Min1.5
Min1.5
Min1.5
0
2