41
/
63
Modem Web Interface
MDM2200
User Manual MDM2200 R3.2 v1.1
Parameter
Description
(Used with Newtec
Terminal Installation
app)
For the combination ANT2010 (75cm) and ILB2120(Ku) this is +/- 90°.
Receive
LNB Type
Determines which type of LNB is used.
Possible values are:
•
Single/Dual
•
Multi band (not applicable for this modem type)
22 kHz Tone
Used to inform the LNB about which frequency band it needs to use.
Refer to the LNB datasheet to know which values to set.
Possible values are:
•
Off
•
On
•
Band selection
Voltage
Used to inform the LNB about which polarization it needs to use. Refer
to the LNB datasheet to know which values to set.
Possible values are:
•
Off
•
Fixed 13 V (only visible when using the 24 Vout power supply)
•
Fixed 18 V (only visible when using the 24 Vout power supply)
•
Band selection (if not set via 22 kHz tone)
Only visible when using the 24 Vout power supply.
•
Polarization selection
Only visible when using the 24 Vout power supply.
Low Band L.O.
Local oscillator frequency (in GHz) used when the LNB is operating in
low band, see the LNB datasheet. Only applicable if ‘Band selection’ is
used in 22 kHz or Voltage settings. If ‘Band selection’ is not used, then
only set one local oscillator frequency (as there is no distinction
between high and low band).
Low Band RF Start
Minimum frequency used by the LNB when operating in low band, see
the LNB datasheet. Only applicable if ‘Band selection’ is used in 22 kHz
or Voltage settings. If ‘Band selection’ is not used, then only set one RF
Start frequency (as there is no distinction between high and low band).
Low Band RF Stop
Maximum frequency used by the LNB when operating in low band, see
the LNB datasheet. Only applicable if ‘Band selection’ is used in 22 kHz
or Voltage settings. If ‘Band selection’ is not used, then only set one RF
Stop frequency (as there is no distinction between high and low band).