© 2021 Copyright Newmar Corporation. All rights reserved. For the most up-to-date version of this content, and for more product-specific information, please refer to Newgle.
162
PLUMBING
CAUTION
!
Never allow the pump to run for long periods of time
without water in the supply tank, as pump damage or
blown fuses may result.
Care and Maintenance
All of the water should be drained from the fresh water
system when the unit is not in use for more than one
week.
Troubleshooting
If water doesn’t flow when a faucet is turned on
while using the demand system, use the following
troubleshooting tips.
If the pump is running, but there is no water:
•
Fill the tank.
•
Clear the water line to the pump or the pump inlet
filter.
•
Rotate the city water / tank fill valve to the correct
position.
If the pump isn’t running:
•
Check the pump switch.
•
Check the 12 Volt fuses.
•
Check the electrical connections.
•
Check the battery.
5. The water pump should stop running once all faucets
are closed.
6. The pump is now ready for automatic operation. The
pump will run when a faucet is opened and stop when
a faucet is closed and the correct pressure has been
reached.
Water Pump Operation via KIB Monitor Panel or
Momentary Contact Switches
This article provides a basic overview of the water pump operation via the KIB Monitor Panel or Momentary Contact Switches.
The water pump may be operated from one or multiple
locations, depending on the coach model, year, and
floorplan.
The water pump may be activated and deactivated via
the KIB Monitor Panel, or, if equipped, via a momentary
contact switch with LED indicator. The KIB switch panels
communicate with a circuit board and touchscreen
monitor on a dedicated V-BUS. The V-BUS receives on/off
commands from the water pump button on the KIB display
monitor or the water pump switch located in the water
compartment.
The KIB circuit board is typically located in the cord
compartment and sends 12 volt power to complete the
water pump circuit. Once the pump pressure switch
makes contact, the pump will supply water pressure to the
fresh water system. The pump will shut off once the pump
pressure switch is satisfied.
Momentary Contact Switches:
•
May be located in the exterior water compartment and/
or inside the coach.
•
May be used with C-Storm or KIB System.
•
Send a ground signal to the KIB board for water pump
activation or deactivation.
KIB L-Panel:
•
May be located in the main coach control panel.
KIB Backlit Multiplex Switch Panel:
•
May be located in various locations through the coach.
•
May be used in conjunction with the KIB L-Panel on
some coaches.
Summary of Contents for Kountry Star 2022