14
MINIMUM 20 SQ IN (130 SQ
CM) OF VENTILATION
REQUIRED ON EACH END OF
CABINET.
MINIMUM 10 SQ IN (65 SQ CM)
OF VENTILATION REQUIRED ON
EACH END OF CABINET.
5"
127mm
MAXIMUM
5"
127mm
MAXIMUM
W
W1
H1
D
H
NON-COMUSTABLE MATERIAL
NON-COMUSTABLE MATERIAL
3"
0.39"
1.19"
ELECTRICAL OPENING
Min 4"
7.5"
2.4"
2.8"
OUTDOOR GFI ELECTRICAL OULET
RECOMMENDED - LOCATE ON SAME SIDE
OF GRILL AS ROTISSERIE BRACKET.
36"
915mm
RECOMMENDED
10in
10in
1in
MINIMUM 10 SQ IN (65 SQ CM)
OF VENTILATION REQUIRED
MINIMUM 20 SQ IN (130 SQ
CM) OF VENTILATION
REQUIRED.
Back View
Installing DSB on custom built cabinet
Layout for Non-combustible enclosure
Configuration Example 1: With closed cutout bottom
Cutout Dimensions
SKU
W
D
H
33” Grill
66900
66910
31.5”
22.3”
11.2”
36” Grill
66903
66913
34.5
22.3”
11.2”
40” Grill
66901
66911
38.5”
22.3”
11.2”
DSB
66902
66912
15.3”
22.4”
11.3”
WARNING
A propane tank can not be
stored below the gas grill.
Only one 20 lbs tank in service
should be used with the grill.
WARNING
• The upper vent opening must be at least 20
square inches for a 20 lb(9.1Kg) propane cylinder.
• The lower vent opening must be at least 10
square inches for a 20 lb(9.1Kg) propane cylinder.
propane tank must be secured to the built-in cabinet
inside the cylinder enclosure.
Note:
These illustrations are for reference purpose only. Actual built-in cabinets and
installation may differ.
Note:
The cabinet should not be designed
in a way that a spare cylinder can be stored
inside the enclosure.
The opening of propane enclosure is limited to
the dimensions below:
Width (W1) must be less than 23.5”.
Height (H1) must be less than 18.5”.