- 106 -
www.NewLeader.com
(800) 363-1771
312884-AA-C
NL345
• Using the control buttons
(Reset,
Run, Stop), run a catch test� If spreading product
that has already been tested, press
to
continue� To begin a test, press
� Conveyor will
run�
•
Once controller dispenses specific amount,
conveyor will stop� Press
to continue�
• Weigh material dispensed and enter actual weight
of material dispensed� Press
to continue�
• It is recommended a minimum of three (3) tests be
done PER PRODUCT to ensure accuracy� Once
each test is done, press “Repeat Calibration” to
run a subsequent test. When finished, press
�
• The main Calibration screen will appear� To
calibrate with a known amount brought to a field,
press
�
Note:
Field totals can be reset from Summary
Screen if needed�
Controller Operations
Summary of Contents for NL345/MULTAPPLIER
Page 6: ...Insert Current New Leader Warranty Warranty...
Page 26: ...26 www NewLeader com 800 363 1771 312884 AA C NL345 Informational Decals 1 1...
Page 86: ...86 www NewLeader com 800 363 1771 312884 AA C NL345 Header Hydraulic Schematic TR3000 Brakes...