26
open circuit
Measure with
multi-meter
Replace the capacitor
short circuit
Measure with
multi-meter
Replace the capacitor
Motor damaged
Motor winding open
circuit
measure the
winding
Replace the motor
Motor winding short
circuit
measure the
winding
measure the winding
Motor winding
grounding
measure the
winding
measure the winding
The
compressor
does not work
Compressor
wiring
terminal
without
power
supply(PCB
no
output)
The machine is
power off
Check the operation
panel
Power on
Setting temperature
is lower than water
temperature
Check setting
temperature
reset
PCB damaged
Substitution method
Replace PCB
Transformer
damaged
Substitution method
Replace transformer
Power cut
Measure the
circuitry voltage
Wait for power supply
Compressor
does not work
Capacitor damaged
Check
the capability of
the capacitor
Replace
the capacitor
External overload protector damaged
Measure protector’s
resistance
Replace
Built-in protector
Too much
refrigerant
Measure pressure,
current and water
temperature
Discharge some
refrigerant
Built-in protector
Too little refrigerant
Measure pressure,
current and water
temperature
parameter
Refill refrigerant
The voltage is low
Measure voltage
Change the lines or
increase voltage regulator
Compressor
cylinder jammed
Measure pressure,
current and water
parameter water
temperature
Shunt capacitor, fill
refrigeration oil