18
backlight turns off.
3.1.7 Display mode, the measured temperature
:
Depending on the operating mode
corresponding to the display, in automatic mode, the temperature display to indicate the tank
temperature, when the water temperature to the temperature, the display mode the measured
temperature of the room.
3.1.8 When set to automatic mode, the display alternately every two seconds tank mode
setting and actual temperature, backwater setting temperature and actual temperature, the
corresponding mode icon also turns lights off and another mode icon.
3.1.9 When a fault is displayed, every two seconds turns the display settings and measured
temperature fault code setting mode.
4. Power outage memory
You can switch the state of the memory operation mode, parameter setting, timing and clock,
when the switch machine state, operating mode, parameter setting, timing changes two
seconds after the wired remote control began to rewrite the EEPROM, memory data when
power is turned on when more than one state when power starts running.
Notice
:
Refrigerant recovery function has no memory.
5. Parameter setting
Touch “
”and”
” together for 3 seconds to enter parameter setting state, the parameter
serial number blinks, touch the "
" and "
" button to check value. Then touch the "
"
button,the parameter content blinks,touch the "
" and "
" button to modify value.Finally
use "
" to save and exit the status.Touch "
" or without operation in 20s then will back to
normal status.
Parameters No. Introductions
Adjust Range
Defaults Remark
P1
Tank setting temp.
35
℃~
60
℃
55
P2
Heating setting temp.
20
℃~
60
℃
45
P3
Cooling setting temp.
10
℃~
20
℃
12
P4
Water tank temp.difference for hot
water heating restarted
0
℃~
15
℃
4
P5
Heating and cooling temp. difference
for restarted
0
℃~
15
℃
3